Arterial spin labeling application in brain: review of reproducibility and reliability
ZHOU Shuai  WU Bing  WU Xin-huai  NIU Guang-ming 

DOI:10.12015/issn.1674-8034.2017.09.011.


[Abstract] Arterial spin labeling (ASL) technique is an emerging technique MR cerebral perfusion technique which can measure the cerebral blood flow quantitatively and noninvasively in genuine. The reliability and reproducibility of the perfusion technique is essential before perfusion imaging data can be pooled from different times or from different scanners. However the reproducibility and reliability of data from ASL is not as robust as imagine. Some work has been done to assess the reproducibility and reliability of data from ASL. This work will have a review on it.
[Keywords] Central nervous system;Arterial spin labeling;Magnetic resonance imaging

ZHOU Shuai Graduate School of Inner Mongolia Medical University, Hohhot 010110, China; Department of Radiology, PLA Army General Hospital, Beijing 100700, China

WU Bing Department of Radiology, PLA Army General Hospital, Beijing 100700, China

WU Xin-huai Department of Radiology, PLA Army General Hospital, Beijing 100700, China

NIU Guang-ming* Department of MRI, First Affiliated Hospital of Inner Mongolia Medical University, Hohhot 010110, China

*Correspondence to: Niu GM, E-mail: cjr.niuguangming@vip.163.com

Conflicts of interest   None.

Received  2017-03-12
Accepted  2017-06-07
DOI: 10.12015/issn.1674-8034.2017.09.011
DOI:10.12015/issn.1674-8034.2017.09.011.

[1]
Warmuth C, Günther M, Zimmer C. Quantification of blood flow in brain tumors: comparison of arterial spin labeling and dynamic susceptibility-weighted contrast-enhanced MR imaging. Radiology, 2003, 228(2): 523-532.
[2]
中华医学会放射学分会质量管理与安全管理学组中华医学会放射学分会磁共振学组.动脉自旋标记脑灌注MRI技术规范化应用专家共识.中华放射学杂志, 2016, 50(11): 817-824.
[3]
Parkes LM, Rashid W, Chard DT, et al. Normal cerebral perfusion measurements using arterial spin labeling: reproducibility, stability, and age and gender effects. Magn Reson Med, 2004, 51(4): 736-743.
[4]
Mezue M, Segerdahl AR, Okell TW, et al. Optimization and reliability of multiple postlabeling delay pseudo-continuous arterial spin labeling during rest and stimulus-induced functional task activation. J Cerebr Blood Flow Metabol, 2014, 34(12): 1919-1927.
[5]
Wu B, Lou X, Wu X, et al. Intra- and interscanner reliability and reproducibility of 3D whole-brain pseudo-continuous arterial spin-labeling MR perfusion at 3 T. J Magn Reson Imaging, 2014, 39(2):402-409.
[6]
Alsop DC, Detre JA, Xavier G, et al. Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: a consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia. Magn Reson Med, 2015, 73(1):102-116.
[7]
Mutsaerts HJ, Steketee RM, Heijtel DF, et al. Inter-vendor reproducibility of pseudo-continuous arterial spin labeling at 3 Tesla. Plos One, 2013, 9(8): e104108.
[8]
Detre JA, Leigh JS, Williams DS, et al. Perfusion imaging. Magn Reson Med, 1992, 23(1): 37-45.
[9]
Roberts DA, Detre JA, Bolinger L, et al. Quantitative magnetic resonance imaging of human brain perfusion at 1.5 T using steady-state inversion of arterial water. Proc Natl Acad Sci U S A. 1994,91(1): 33-37.
[10]
Gevers S, Majoie CB, Xw VD, et al. Acquisition time and reproducibility of continuous arterial spin-labeling perfusion imaging at 3 T. AJNR Am J Neuroradiol, 2009, 30(5): 968-971.
[11]
Tatewaki Y, Higano S, Taki Y, et al. Regional reliability of quantitative signal targeting with alternating radiofrequency (STAR) labeling of arterial regions (QUASAR). J Neuroimaging, 2014,24(6): 554-561.
[12]
Gevers S, van Osch MJ, Bokkers RP, et al. Intra- and multicenter reproducibility of pulsed, continuous and pseudo-continuous arterial spin labeling methods for measuring cerebral perfusion. J Cerebr Blood Flow Metabol, 2011, 31(8): 1706-1715.
[13]
Mutsaerts HJ, van Osch MJ, Zelaya FO, et al. Multi-vendor reliability of arterial spin labeling perfusion MRI using a near-identical sequence: Implications for multi-center studies. Neuroimag, 2015, (113): 143-152.
[14]
Parkes LM, Rashid W, Chard DT, et al. Normal cerebral perfusion measurements using arterial spin labeling: reproducibility, stability, and age and gender effects. Magn Reson Med, 2004, 51(4): 736-743.
[15]
Emily K, Liana A, Collin L, et al. Reliability of two-dimensional and three-dimensional pseudo-continuous arterial spin labeling perfusion MRI in elderly populations: comparison with 15O-water positron emission tomography. J Magn Reson Imaging, 2014, 39(4): 931-939.
[16]
娄昕,吴冰,黄点点,等.正常成人后循环脑区动脉自旋标记灌注成像的可重复性研究.中华放射学杂志, 2014, 48(2): 151-154.
[17]
娄昕,吴冰,吴新淮,等.正常成人听皮层磁共振动脉自旋标记灌注成像的可重复性研究.中华耳科学杂志, 2013, 11(1): 54-58.
[18]
Huang D, Wu B, Shi K, et al. Reliability of three-dimensional pseudo-continuous arterial spin labeling mr imaging for measuring visual cortex perfusion on two 3t scanners. Plos One, 2013, 8(11):e79471-e79471.
[19]
Gevers S, Bokkers RP, Hendrikse J, et al. Robustness and reproducibility of flow territories defined by planning-free vessel-encoded pseudocontinuous arterial spin-labeling. AJNR Am J Neuroradiol, 2011, 33(2): 21-55.
[20]
Donahue M, Jezzard P. MR perfusion imaging in neuroscience//Barker P, Golay X, Zaharchuk G. Clinical perfusion MRI: techniques and applications, 1st ed. Cambridge: Cambridge University Press, 2013: 114-117.
[21]
George E, Becerra L, Upadhyay J, et al. Evaluation of novel drugs using fMRI in early-phase clinical trials: safety monitoring. Drug Discovery Today, 2010, 15(15-16): 684-689.
[22]
Handley R, Zelaya FO, Reinders AA, et al. Acute effects of single-dose aripiprazole and haloperidol on resting cerebral blood flow (rCBF) in the human brain. Human Brain Mapping, 2013, 34(2):272-282.
[23]
Mutsaerts HJ, Steketee RM, Heijtel DF, et al. Reproducibility of pharmacological ASL using sequences from different vendors: implications for multicenter drug studies. MAGMA, 2015, 28(5):427-436.
[24]
Tancredi FB, Lajoie I, Hoge RD. Test-retest reliability of cerebral blood flow and blood oxygenation level-dependent responses to hypercapnia and hyperoxia using dual-echo pseudo-continuous arterial spin labeling and step changes in the fractional composition of inspired gases. J Magn Reson Imaging, 2015, 42(4): 1144-1157.
[25]
Yen YF, Field AS, Martin EM, et al. Test-retest reproducibility of quantitative CBF measurements using FAIR perfusion MRI and acetazolamide challenge. Magn Reson Med, 2002, 47(5): 921-928.
[26]
Demeter E, Hernandez-Garcia L, Sarter M, et al. Challenges to attention: a continuous arterial spin labeling (ASL) study of the effects of distraction on sustained attention. Neuroimage, 2011,54(2): 1518-29.
[27]
Fernández-Seara MA, Wang J, Wang Z, et al. Imaging mesial temporal lobe activation during scene encoding: comparison of fMRI using BOLD and arterial spin labeling. Human Brain Mapping, 2007, 28(12): 1391-1400.
[28]
Kemeny S, Ye FQ, Birn R, et al. Comparison of continuous overt speech fMRI using BOLD and arterial spin labeling. Human Brain Mapping, 2005, 24(3): 173-183.
[29]
Cavusoglu M, Bartels A, Yesilyurt B, et al. Retinotopic maps and hemodynamic delays in the human visual cortex measured using arterial spin labeling. Neuroimage, 2012, 59(4): 4044-4054.
[30]
Wang J, Aguirre GK, Kimberg DY, et al. Arterial spin labeling perfusion fMRI with very low task frequency. Magn Reson Med, 2003, 49(5): 796-802.
[31]
Steketee RM, Mutsaerts HJ, Bron EE, et al. Quantitative functional arterial spin labeling (fASL) MRI - sensitivity and reproducibility of regional CBF changes using pseudo-continuous ASL product sequences. Plos One, 2015, 10(7): e0132929.

PREV Anaphylactic shock caused by Ga-dobenate dimeglumine was in timely treated successfully: a case report
NEXT Advances of MR imaging on differential diagnosis between recurrence of glioma and radiation-induced brain injury
  



Tel & Fax: +8610-67113815    E-mail: editor@cjmri.cn