Share:
Share this content in WeChat
X
Review
Research advances of functional MRI in placenta
WANG Feng  LIU Jian-yu 

DOI:10.12015/issn.1674-8034.2018.03.014.


[Abstract] The evaluation of placental function is essential to the understanding and diagnosis of pregnancy complications. In recent years, functional MRI is applied more and more in both animal models and clinical research in placenta, which could provide useful information on physiological functions of placenta, including vascularization, oxygenation, metabolism and diffusion within tissues. Functional MRI shows great research value and clinical applying foreground.
[Keywords] Magnetic resonance imaging;placenta;Functional imaging

WANG Feng Department of Radiology, Peking University Third Hospital, Beijing 100191, China

LIU Jian-yu* Department of Radiology, Peking University Third Hospital, Beijing 100191, China

*Corresponding to: Liu JY, E-mail: jyliubysy@163.com

Conflicts of interest   None.

Received  2017-11-01
Accepted  2018-01-10
DOI: 10.12015/issn.1674-8034.2018.03.014
DOI:10.12015/issn.1674-8034.2018.03.014.

[1]
Siauve N, Chalouhi G E, Deloison B, et al. Functional imaging of the human placenta with magnetic resonance. Am J Obstet Gynecol, 2015, 213(4Suppl): S103-S114.
[2]
Salomon LJ, Siauve N, Balvay D, et al. Placental perfusion MR imaging with contrast agents in a mouse model. Radiology, 2005, 235(1): 73-80.
[3]
Taillieu F, Salomon LJ, Siauve N, et al. Placental perfusion and permeability: simultaneous assessment with dual-echo contrast-enhanced MR imaging in mice. Radiology, 2006, 241(3): 737-745.
[4]
Salomon LJ, Siauve N, Taillieu F, et al. In vivo dynamic MRI measurement of the noradrenaline-induced reduction in placental blood flow in mice. Placenta, 2006, 27(9-10): 1007-1013.
[5]
Tomlinson TM, Garbow JR, Anderson JR, et al. Magnetic resonance imaging of hypoxic injury to the murine placenta. Am J Physiol Regul Integr Comp Physiol, 2010, 298(2): R312-R319.
[6]
Plaks V, Sapoznik S, Berkovitz E, et al. Functional phenotyping of the maternal albumin turnover in the mouse placenta by dynamic contrast-enhanced MRI. Mol Imaging Biol, 2011, 13(3): 481-492.
[7]
Plaks V, Berkovitz E, Vandoorne K, et al. Survival and size are differentially regulated by placental and fetal PKBalpha/AKT1 in mice. Biol Reprod, 2011, 84(3): 537-545.
[8]
Remus CC, Sedlacik J, Wedegaertner U, et al. Application of the steepest slope model reveals different perfusion territories within the mouse placenta. Placenta, 2013, 34(10): 899-906.
[9]
Kording F, Forkert ND, Sedlacik J, et al. Automatic differentiation of placental perfusion compartments by time-to-peak analysis in mice. Placenta, 2015, 36(3): 255-261.
[10]
Yadav B K, Neelavalli J, Krishnamurthy U, et al. A longitudinal study of placental perfusion using dynamic contrast enhanced magnetic resonance imaging in murine pregnancy. Placenta, 2016, 43: 90-97.
[11]
Brix G, Zwick S, Griebel J, et al. Estimation of tissue perfusion by dynamic contrast-enhanced imaging: simulation-based evaluation of the steepest slope method. Eur Radiol, 2010, 20(9): 2166-2175.
[12]
Frias AE, Schabel MC, Roberts VH, et al. Using dynamic contrast-enhanced MRI to quantitatively characterize maternal vascular organization in the primate placenta. Magn Reson Med, 2015, 73(4): 1570-1578.
[13]
Brunelli R, Masselli G, Parasassi T, et al. Intervillous circulation in intra-uterine growth restriction. Correlation to fetal well being. Placenta, 2010, 31(12): 1051-1056.
[14]
Millischer AE, Deloison B, Silvera S, et al. Dynamic contrast enhanced MRI of the placenta: A tool for prenatal diagnosis of placenta accreta? Placenta, 2017, 53: 40-47.
[15]
Gowland PA, Francis ST, Duncan KR, et al. In vivo perfusion measurements in the human placenta using echo planar imaging at 0.5 T. Magn Reson Med,1998,40(3): 467-473.
[16]
Francis ST, Duncan KR, Moore RJ, et al. Non-invasive mapping of placental perfusion. Lancet, 1998, 351(9113): 1397-1399.
[17]
Derwig I, Lythgoe DJ, Barker GJ, et al. Association of placental perfusion, as assessed by magnetic resonance imaging and uterine artery Doppler ultrasound, and its relationship to pregnancy outcome. Placenta, 2013, 34(10): 885-891.
[18]
Avni R, Raz T, Biton IE, et al. Unique in utero identification of fetuses in multifetal mouse pregnancies by placental bidirectional arterial spin labeling MRI. Magn Reson Med, 2012, 68(2): 560-570.
[19]
Raz T, Avni R, Addadi Y, et al. The hemodynamic basis for positional- and inter-fetal dependent effects in dual arterial supply of mouse pregnancies. PLoS One, 2012, 7(12): e52273.
[20]
Zhao SH. Cardiac MR: recent technical developments. Chin J Magn Reson Imaging, 2014, 5(Suppl 1): 73-77.赵世华.心脏磁共振技术新进展.磁共振成像, 2014, 5(z1): 73-77.
[21]
Wedegartner U, Tchirikov M, Schafer S, et al. Functional MR imaging: comparison of BOLD signal intensity changes in fetal organs with fetal and maternal oxyhemoglobin saturation during hypoxia in sheep. Radiology, 2006, 238(3): 872-880.
[22]
Girsh E, Plaks V, Gilad AA, et al. Cloprostenol, a prostaglandin F(2alpha) analog, induces hypoxia in rat placenta: BOLD contrast MRI. NMR Biomed, 2007, 20(1): 28-39.
[23]
Huen I, Morris DM, Wright C, et al. R1 and R2* changes in the human placenta in response to maternal oxygen challenge. Magn Reson Med, 2013, 70(5): 1427-1433.
[24]
Sorensen A, Peters D, Frund E, et al. Changes in human placental oxygenation during maternal hyperoxia estimated by blood oxygen level-dependent magnetic resonance imaging (BOLD MRI). Ultrasound Obstet Gynecol, 2013, 42(3): 310-314.
[25]
Aimot-Macron S, Salomon LJ, Deloison B, et al. In vivo MRI assessment of placental and foetal oxygenation changes in a rat model of growth restriction using blood oxygen level-dependent (BOLD) magnetic resonance imaging. Eur Radiol, 2013, 23(5): 1335-1342.
[26]
Chalouhi GE, Alison M, Deloison B, et al. Fetoplacental oxygenation in an intrauterine growth restriction rat model by using blood oxygen level-dependent MR imaging at 4.7 T. Radiology, 2013, 269(1): 122-129.
[27]
Ingram E, Morris D, Naish J, et al. MR Imaging Measurements of Altered Placental Oxygenation in Pregnancies Complicated by Fetal Growth Restriction. Radiology, 2017: 162385.
[28]
Sorensen A, Sinding M, Peters DA, et al. Placental oxygen transport estimated by the hyperoxic placental BOLD MRI response. Physiol Rep, 2015, 3(10 DOI: ): e12582.
[29]
Luo J, Abaci TE, Bibbo C, et al. In Vivo Quantification of Placental Insufficiency by BOLD MRI: A Human Study. Sci Rep, 2017, 7(1): 3713.
[30]
Avni R, Golani O, Akselrod-Ballin A, et al. MR Imaging-derived Oxygen-Hemoglobin Dissociation Curves and Fetal-Placental Oxygen-Hemoglobin Affinities. Radiology, 2016, 280(1): 68-77.
[31]
Wang F, Liu JY. The diagnostic values of diffusion-weighted imaging for ovarian cancer. Chin J MagnReson Imaging, 2016, 7(8): 572-576.王丰,刘剑羽.磁共振扩散加权成像在卵巢癌中的诊断价值.磁共振成像, 2016, 7(8): 572-576.
[32]
Manganaro L, Fierro F, Tomei A, et al. MRI and DWI: feasibility of DWI and ADC maps in the evaluation of placental changes during gestation. Prenat Diagn, 2010, 30(12-13): 1178-1184.
[33]
Moore RJ, Issa B, Tokarczuk P, et al. In vivo intravoxel incoherent motion measurements in the human placenta using echo-planar imaging at 0.5 T. Magn Reson Med, 2000, 43(2): 295-302.
[34]
Moore RJ, Ong SS, Tyler DJ, et al. Spiral artery blood volume in normal pregnancies and those compromised by pre-eclampsia. NMR Biomed, 2008, 21(4): 376-380.
[35]
Sohlberg S, Mulic-Lutvica A, Lindgren P, et al. Placental perfusion in normal pregnancy and early and late preeclampsia: a magnetic resonance imaging study. Placenta, 2014, 35(3): 202-206.
[36]
Capuani S, Guerreri M, Antonelli A, et al. Diffusion and perfusion quantified by Magnetic Resonance Imaging are markers of human placenta development in normal pregnancy. Placenta, 2017, 58: 33-39.
[37]
Moore RJ, Strachan BK, Tyler DJ, et al. In utero perfusing fraction maps in normal and growth restricted pregnancy measured using IVIM echo-planar MRI. Placenta, 2000, 21(7): 726-732.
[38]
Alison M, Chalouhi GE, Autret G, et al. Use of intravoxel incoherent motion MR imaging to assess placental perfusion in a murine model of placental insufficiency. Invest Radiol, 2013, 48(1): 17-23.
[39]
Bonel HM, Stolz B, Diedrichsen L, et al. Diffusion-weighted MR imaging of the placenta in fetuses with placental insufficiency. Radiology, 2010, 257(3): 810-819.
[40]
Javor D, Nasel C, Schweim T, et al. In vivo assessment of putative functional placental tissue volume in placental intrauterine growth restriction (IUGR) in human fetuses using diffusion tensor magnetic resonance imaging. Placenta, 2013, 34(8): 676-680.
[41]
Morita S, Ueno E, Fujimura M, et al. Feasibility of diffusion-weighted MRI for defining placental invasion. J Magn Reson Imaging, 2009, 30(3): 666-671.
[42]
Solomon E, Avni R, Hadas R, et al. Major mouse placental compartments revealed by diffusion-weighted MRI, contrast-enhanced MRI, and fluorescence imaging. Proc Natl Acad Sci U S A, 2014, 111(28): 10353-10358.
[43]
You W, Andescavage N, Zun Z, et al. Semi-automatic segmentation of the placenta into fetal and maternal compartments using intravoxel incoherent motion MRI. Proc SPIE Int Soc Opt Eng, 2017, 10137( DOI: ) :1013726.
[44]
Weindling AM, Griffiths RD, Garden AS, et al. Phosphorus metabolites in the human placenta estimated in vivo by magnetic resonance spectroscopy. Arch Dis Child, 1991, 66(7 DOI: ): 780-782.
[45]
Sohlberg S, Wikstrom AK, Olovsson M, et al. In vivo (3)(1)P-MR spectroscopy in normal pregnancy, early and late preeclampsia: a study of placental metabolism. Placenta, 2014, 35(5): 318-323.
[46]
Denison FC, Semple SI, Stock SJ, et al. Novel use of proton magnetic resonance spectroscopy (1HMRS) to non-invasively assess placental metabolism. PLos One, 2012, 7(8): e42926.
[47]
Macnaught G, Gray C, Walker J, et al. (1)H MRS: a potential biomarker of in utero placental function. NMR Biomed, 2015, 28(10): 1275-1282.
[48]
Krishnamurthy U, Szalai G, Neelavalli J, et al. Quantitative T2 changes and susceptibility-weighted magnetic resonance imaging in murine pregnancy. Gynecol Obstet Invest, 2014, 78(1): 33-40.

PREV A case of antipsychotic medication induced heat stroke
NEXT Research advances of functional MRI in placenta
  



Tel & Fax: +8610-67113815    E-mail: editor@cjmri.cn