Share:
Share this content in WeChat
X
Review
Progress in the application of ultrashort echo time magnetic resonance imaging in musculoskeletal system
LIU Jungu  ZHANG Jin 

Cite this article as: Liu JG, Zhang J. Progress in the application of ultrashort echo time magnetic resonance imaging in musculoskeletal system. Chin J Magn Reson Imaging, 2020, 11(2): 158-160. DOI:10.12015/issn.1674-8034.2020.02.017.


[Abstract] MRI is a conventional imaging technique for the diagnosis of skeletal muscle tissue diseases, but many skeletal muscle tissues can not be clearly displayed on conventional MRI images because of their inherent short T2 values. With the application and development of ultrashort echo time (UTE) MRI technology, short T2 tissue can be directly imaged and quantitatively described. This paper gives a brief review of UTE MRI technology and its application in bone and muscle system.
[Keywords] ultrashort echo time series;magnetic resonance imaging;short T2 tissues;skeletal muscle system

LIU Jungu Department of Medical Imaging, Shanxi Medical University, Taiyuan 030001, China

ZHANG Jin* Department of Radiology, Second Hospital of Shanxi Medical University, Taiyuan 030001, China

*Corresponding to: Zhang J, E-mail: zhangjin7007@aliyun.com

Conflicts of interest   None.

Received  2019-08-20
Accepted  2020-01-03
DOI: 10.12015/issn.1674-8034.2020.02.017
Cite this article as: Liu JG, Zhang J. Progress in the application of ultrashort echo time magnetic resonance imaging in musculoskeletal system. Chin J Magn Reson Imaging, 2020, 11(2): 158-160. DOI:10.12015/issn.1674-8034.2020.02.017.

[1]
李莎,张艺宝,吴昊,等.核磁共振超短回波时间序列技术研究进展.中国医学物理学杂志, 2019, 36(1): 55-59.
[2]
Rahme J, Börnert P, Groen J, et al. Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling. Magn Reson Med, 2006, 55(5): 1075-1082.
[3]
陈宁,袁慧书.超短回波时间磁共振成像应用进展.中国介入影像与治疗学, 2016, 13(6): 378-381.
[4]
高嵩,杜江,包尚联.超短回波磁共振成像与骨质量检测.中国医学物理学杂志, 2013, 30(2): 4004-4007.
[5]
Du J, Bydder GM. Qualitative and quantitative ultrashort-TE MRI of cortical bone. NMR Biomed, 2013, 26(5): 489-506.
[6]
Johnson EM, Vyas U, Ghanouni P, et al. Improved cortical bone specificity in UTE MR Imaging. Magn Reson Med, 2017, 77(2): 684-695.
[7]
Shao H, Chang EY, Pauli C, et al. UTE bi-component analysis of T2* relaxation in articular cartilage. Osteoarthritis Cartilage, 2016, 24(2): 364-373.
[8]
Rahmer J, Börnert P, Groen J, et al. Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling. Magn Reson Med, 2006, 55(5): 1075-1082.
[9]
Techawiboonwong A, Song HK, Wehrli FW. In vivo MRI of submillisecond T(2) species with two-dimensional and three-dimensional radial sequences and applications to the measurement of cortical bone water. NMR Biomed, 2008, 21(1): 59-70.
[10]
Carl M, Bydder GM, Du J. UTE imaging with simultaneous water and fat signal suppression using a time-efficient multispoke inversion recovery pulse sequence. Magn Reson Med, 2016, 76(2): 577-582.
[11]
Li C, Magland JF, Zhao X, et al. Selective in vivo bone imaging with long-T suppressed PETRA MRI. Magn Reson Med, 2017, 77(3): 989-997.
[12]
Reichert IL, Robson MD, Gatehouse PD, et al. Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences. Magn Reson Imaging, 2005, 23(5): 611-618.
[13]
Ma YJ, Tadros A, Du J, et al. Quantitative two-dimensional ultrashort echo time magnetization transfer (2D UTE-MT) imaging of cortical bone. Magn Reson Med, 2018, 79(4): 1941-1949.
[14]
Jerban S, Ma Y, Wong JH, et al. Ultrashort echo time magnetic resonance imaging (UTE-MRI) of cortical bone correlates well with histomorphometric assessment of bone microstructure. Bone, 2019, 123: 8-17.
[15]
Lu X, Jerban S, Wan L, et al. Three-dimensional ultrashort echo time imaging with tricomponent analysis for human cortical bone. Magn Reson Med, 2019, 82(1): 348-355.
[16]
Wan LD, Wu M, Sheth V, et al. Evaluation of cortical bone perfusion using dynamic contrast enhanced ultrashort echo time imaging: a feasibility study. Quant Imaging Med Surg, 2019, 9(8): 1383-1393.
[17]
Zhu Y, Cheng X, Ma Y, et al. Rotator cuff tendon assessment using magic-angle insensitive 3D ultrashort echo time cones magnetization transfer (UTE-Cones-MT) imaging and modeling with histological correlation. Magn Reson Imaging, 2018, 48(1): 160-168.
[18]
Chen B, Cheng X, Dorthe EW, et al. Evaluation of normal cadaveric achilles tendon and enthesis with ultrashort echo time (UTE) magnetic resonance imaging and indentation testing. NMR Biomed, 2019, 32(1): e4034.
[19]
Oatridge A, Herlihy A, Thomas RW, et al. Magic angle imaging of the achilles tendon in patients with chronic tendonopathy. Clinical Radiology, 2003, 58(5): 384-388.
[20]
Wright P, Jellus V, Mcgonagle D, et al. Comparison of two ultrashort echo time sequences for the quantification of T1 within phantom and human Achilles tendon at 3 T. Magn Reson Med, 2012, 68(4): 1279-1284.
[21]
Wang N, Xia Y. Anisotropic analysis of multi-component T2 and T1ρ relaxations in achilles tendon by NMR spectroscopy and microscopic MRI. Magn Reson Imaging, 2013, 38(3): 625-633.
[22]
Chang EY, Du J, Statum S, et al. Quantitative bi-component T2* analysis of histologically normal achilles tendons. Muscles Ligaments Tendons J, 2015, 5(2): 58-62.
[23]
Chang EY, Du J, Biswas R, et al. Off-resonance saturation ratio obtained with ultrashort echo time-magnetization transfer techniques is sensitive to changes in static tensile loading of tendons and degeneration. Magn Reson Imaging, 2015, 42(4): 1064-1071.
[24]
Zhu Y, Cheng X, Ma Y, et al. Rotator cuff tendon assessment using magic-angle insensitive 3D ultrashort echo time cones magnetization transfer (UTE-Cones-MT) imaging and modeling with histological correlation. Magn Reson Imaging, 2018, 48(1): 160-168.
[25]
Gatehouse PD, He T, Puri BK, et al. Contrast-enhanced MRI of the menisci of the knee using ultrashort echo time (UTE) pulse sequences: imaging of the red and white zones. Br J Radiol, 2004, 77(920): 641-647.
[26]
Bae WC, Dwek JR, Znamirowski R, et al. Ultrashort echo time MR imaging of osteochondral junction of the knee at 3 T: identification of anatomic structures contributing to signal intensity. Radiology, 2010, 254(3): 837-845.
[27]
Ma YJ, Jerban S, Carl M, et al. Imaging of the region of the osteochondral junction (OCJ) using a 3D adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-cones) sequence at 3 T. NMR Biomed, 2019, 32(5): e4080.
[28]
Wheaton AJ, Dodge GR, Elliott DM, et al. Quantification of cartilage biomechanical and biochemical properties via T1ρ magnetic resonance imaging. Magn Reson Med, 2005, 54(5): 1087-1093.
[29]
Bae WC, Biswas R, Statum S, et al. Sensitivity of quantitative UTE MRI to the biomechanical property of the temporomandibular joint disc. Skeletal Radiol, 2014, 43(9): 1217-1223.
[30]
Ma YJ, Carl M, Searleman A, et al. 3D adiabatic T prepared ultrashort echo time cones sequence for whole knee imaging. Magn Reson Med, 2018, 80(4): 1429-1439.
[31]
Pauli C, Bae WC, Lee M, et al. Ultrashort-echo time MR imaging of the patella with bicomponent analysis: correlation with histopathologic and polarized light microscopic findings. Radiology, 2012, 264(2): 484-493.
[32]
Gullbrand SE, Peterson J, Ahlborn J, et al. ISSLS prize winner: Dynamic loading-induced convective transport enhances intervertebral disc nutrition. Spine, 2015, 40(15): 1158-1164.
[33]
Bae WC, Statum S, Zhang Z, et al. Morphology of the cartilaginous endplates in human intervertebral disks with ultrashort echo time MR imaging. Radiology, 2013, 266(2): 564-574.
[34]
Bae WC, Du J, Bydder GM, et al. Conventional and ultrashort time-to-echo magnetic resonance imaging of articular cartilage, meniscus, and intervertebral disk. Top Magn Reson Imaging, 2010, 21(5): 275-289.
[35]
Law T, Anthony MP, Chan Q, et al. Ultrashort time-to-echo MRI of the cartilaginous endplate: technique and association with intervertebral disc degeneration. Med Imaging Radiat Oncol, 2013, 57(4): 427-434.
[36]
Schneiderman G, Flannigan B, Kingston S, et al. Magnetic resonance imaging in the diagnosis of disc degeneration: correlation with discography. Spine, 1987, 12(3): 276-281.
[37]
潘希敏,胡美玉,江波.腰椎软骨终板的MR三维超短回波时间T2* mapping定量评价.磁共振成像, 2014, 5(2): 111-114.

PREV Hemophiliac arthritis: Two cases report and literature review
NEXT Computational fluid dynamics analysis of hemorrhagic transformation after reperfusion therapy in acute ischemic stroke patients with middle cerebral artery occlusion
  



Tel & Fax: +8610-67113815    E-mail: editor@cjmri.cn