Share:
Share this content in WeChat
X
Experience Exchanges
Imaging features of multi-mode multi-parameter magnetic resonance imaging in the diagnosis of placenta accreta
WU Huifeng  HE Yu’e  MO Jingxiong  YU Shanshan  LUO Taizhao  ZHAI Yongchuan  WANG Yetao  ZHOU Huo 

Cite this article as: Wu HF, He YE, Mo JX, et al. Imaging features of multi-mode multi-parameter magnetic resonance imaging in the diagnosis of placenta accreta[J]. Chin J Magn Reson Imaging, 2021, 12(6): 102-105. DOI:10.12015/issn.1674-8034.2021.06.020.


[Abstract] Objective To investigate the imaging features of multi-mode and multi-parameter magnetic resonance examination in the diagnosis of placenta accreta. Materials andMethods The routine magnetic resonance imaging and multiple b value DWI were performed in 69 pregnant women with placenta accreta as placenta accreta group and 56 pregnant women without placenta accreta as control group. Placenta accreta was analyzed in routine rapid magnetic resonance imaging sequence and multiple b value DWI.Results The routine sequence showed: ①The placental patchy low signal shadow was found in both balance turbo field echo (BTFE) and single-shot fast spin-echo (SSFSE) sequences (called "sentinel black spot", with the most effective diagnosis) accounting for 49.28% (34/69);②The low signal lines of placenta and myometrium disappeared accounting for 62.32% (43/69); ③The mother's face of placenta was locally raised or wavy accounting for 73.91% (51/69); ④Anomalous increase of subfacial sinuses in placenta accounting for 71.01% (49/69). All four imaging features were statistically significant (P<0.05). DWI manifestations: placental tissue signals penetrated myometrium in 12 cases, placental nail-like, nodular protrusion into myometrium in 24 cases, there were 46 cases with localized protuberance or wavy appearance of placenta mother, at placenta accreta DWI signal increased slightly, rough 19 cases, 6 cases of signal reduction at b0 placenta implantation, all the five imaging features were statistically significant (P<0.05).Conclusions Multi mode and multi parameter MRI can provide reliable MRI features in the diagnosis of placenta accreta.
[Keywords] magnetic resonance imaging;diffusion-weighted imaging;placenta accreta;imaging features;multiparameter;multimodality

WU Huifeng*   HE Yu’e   MO Jingxiong   YU Shanshan   LUO Taizhao   ZHAI Yongchuan   WANG Yetao   ZHOU Huo  

Department of Radiology, Hezhou People's Hospital, Hezhou 542899, China

Wu HF, E-mail: huifengwu@yeah.net

Conflicts of interest   None.

This work was part of Scientific Research and Technology Development Plan of Hezhou City (No. hekegong 1910007).
Received  2021-01-14
Accepted  2021-03-05
DOI: 10.12015/issn.1674-8034.2021.06.020
Cite this article as: Wu HF, He YE, Mo JX, et al. Imaging features of multi-mode multi-parameter magnetic resonance imaging in the diagnosis of placenta accreta[J]. Chin J Magn Reson Imaging, 2021, 12(6): 102-105. DOI:10.12015/issn.1674-8034.2021.06.020.

1
Feng YJ. Obstetrics and gynecology[M]. Beijing: People's Health Publishing House, 2010: 113-119.
2
Shlomit M, Maymon R, Jacob B, et al. Comparison of approaches for placenta accrete: Uterrine preservation versus cesarean hysterectomy[J]. Harefuah, 2018, 157(11): 696-700.
3
Kapoor H, Hanaoka M, Dawkins A, et al. Review of MRI imaging for placenta accreta spectrum: Pathophysiologic insights, imaging signs, and recent developments[J]. Placenta, 2021, 104: 31-39. DOI: 10.1016/j.placenta.2020.11.004.
4
Baughman WC,Corteville JE, Shah RR. Placenta accreta: Spectrum of US and MR imaging findings[J]. Radio Graphics, 2008, 28(7): 1905-1916. DOI: 10.1148/rg.287085060.
5
Zhou WM, He L, Fu WD, et al. The value of MRI in the diagnosis of placenta previa and placenta accreta[J]. J Clin Res, 2016, 33(8): 1659-1662. DOI: 10.3969/j.issn.1671-7171.2016.08.075.
6
Lu W, Cao MR, Wu YC, et al. The analysis of diagnostic value of MRI features for the placenta percreta invading the urinary bladde[J]. Radiol Pract, 2020, 35(10): 1297-1302. DOI: 10.13609/j.cnki.1000-0313.2020.10.017.
7
Zheng CN, Yang TH, Lin JZ, et al. MRI in the diagnosis of placenta accreta[J]. Chin J Magn Reson Imaging, 2017, 8(8): 593-597. DOI: 10.12015/issn.1674-8034.2017.08.007.
8
Chen X, Shan RQ, Wang GB, et al. MRI findings of penetrating placenta accreta[J]. Chin J Radiol, 2015, 49(11): 833-837. DOI: 10.3760/cma.j.issn.1005-1201.2015.11.007.
9
Cao MR, Du M, Huang Y, et al. MRI features of placenta accreta[J]. Chin J Radiol, 2012, 46(7): 629-632. DOI: 10.3760/cma.j.issn.1005-1201.2012.07.011.
10
Familiari A, Liberati M, Lim P, et al. Diagnostic accuracy of magnetic resonance imaging indetecting the severity of abnormal invasive placenta: a systematic review and meta-analysis[J]. Acta Obstet Gynecol Scand, 2018, 97(5): 507-520. DOI: 10.1111/aogs.13258.
11
Charis B, Konstantina Z, Stavros F, et al. MRI prognosticators for adverse maternal and neonatal clinical outcome in patients at high risk for placenta accreta spectrum (PAS) disorders[J]. J Magn Reson Imaging, 2019, 50(2): 602-618. DOI: 10.1002/jmri.26592.
12
Fiocchi F, Monelli F, Besutti G, et al. MRI of placenta accreta: diagnostic accuracy and impact of interventional radiology on foetal-maternal delivery outcomes in high-risk women[J]. Br J Radiol, 2020, 93(1114): 20200267. DOI: 10.1259/bjr.20200267.
13
Srisajjakul S, Prapaisilp P, Bangchokdee S. MRI of placenta accreta spectrum: a step-by-step approach[J]. Korean J Radiol, 2021, 22(2): 198-212. DOI: 10.3348/kjr.2020.0580.
14
Clark HR, Ng TW, Khan A, et al. Placenta accreta spectrum: Correlation of MRI parameters with pathologic and surgical outcomes of high-risk pregnancies[J]. AJR Am J Roentgenol, 2020, 214(6): 1417-1423. DOI: 10.2214/AJR.19.21705.
15
Guillon S, Levaillant J, Gitz L, et al. OP19.04: Interest of MRI sonography fusion for the diagnosis of placenta accreta[J]. Ultrasound in Obstetrics & Gynecology, 2019, 54: 149-149. DOI: 10.1002/uog.20838.
16
Charis B, Konstantinidou AE, Zafeiropoulou K, et al. Intraplacental fetal vessel diameter may help predict for placental invasiveness in iregnant women at high risk for placenta accreta spectrum disorders[J]. Radiology, 2020, 298(2): 403-412. DOI: 10.1148/radiol.2020200273.
17
D'Antonio F, lacovella C, Bhide A, et al. Prenatal identification of invasive placentation using magnetic resonance imaging: systemmatic review and mata-analysis[J]. Ultrasound Obst Gyn, 2014, 44(1): 8-16. DOI: 10.1002/uog.13327.
18
Cao MR, Liu BG, Guo JM, et al. New MRI signs of placenta accreta[J]. J Clin Radiol, 2016, 35(6): 899-902.
19
Long GY, Chen TZ, Feng TY, et al. MRI features of placenta accreta[J]. Chin Comput Med Imaging, 2017, 23(1): 77-81. DOI: 10.3969/j.issn.1006-5741.2017.01.015.
20
Quyen N, PhD Do, Matthew A, et al. MRI of the placenta accreta spectrum (PAS) disorder: Radiomics analysis correlates with surgical and pathological outcome[J]. J Magn Reson Imaging, 2020, 51(3): 936-946. DOI: 10.1002/jmri.26883.
21
Finazzo F, D'antonio F, Masselli G, et al. Interobserver agreement in MRI assessment of severity of placenta accreta spectrum disorders[J]. Ultrasound in Obstetrics & Gynecology, 2020, 55(4): 467-473. DOI: 10.1002/uog.20381.
22
Sannananja B, Ellermeier A, Hippe DS, et al. Utility of diffusion-weighted MR imaging in the diagnosis of placenta accreta spectrum abnormality[J]. Abdom Radiol, 2018, 43(11): 3147-3156. DOI: 10.1007/s00261-018-1599-8.

PREV Predictive effect of Gd-EOB-DTPA enhanced MRI for HBV-related diameter ≤1 cm sHCC intrahepatic metastasis
NEXT Epidermoid cyst of the adrenal gland: A case report
  



Tel & Fax: +8610-67113815    E-mail: editor@cjmri.cn