Common artifacts in 3 T high-field MRI systems: principle, appearance and remedy
YIN Jian-zhong 

DOI:10.3969/j.issn.1674-8034.2010.04.011.


[Abstract] MRI systems at a field-strength of 3 T has been used more and more frequently in recent years. The high-field systems, not only can benefit the imaging quality, but also can cause some artifacts. These artifacts are caused either by physical limitations related to the high-field strength or by protocols that are not yet fully optimized for the high-field strength. The most common artifacts will be analyzed in this paper, in order to mitigate or avoid them and take best advantage of high-field 3 T system.
[Keywords] Magnetic resonance imaging;High field;Artifacts

YIN Jian-zhong Department of Radiology, Tianjin First Center Hospital, Tianjin 300192, China

Correspondence to: Yin JZ, E-mail: jianzhong.yin@gmail.com

Conflicts of interest   None.

Received  2010-02-26
Accepted  2010-04-15
DOI: 10.3969/j.issn.1674-8034.2010.04.011
DOI:10.3969/j.issn.1674-8034.2010.04.011.

[1]
Nakada T. Clinical experience on 3.0 T systems in Niigata, 1996 to 2002. Invest Radiol, 2003, 38(7): 377-384.
[2]
Nael K, Fenchel MC, Kramer U, et al. Whole-body contrast-enhanced magnetic resonance angiography: new advances at 3.0 T. Top Magn Reson Imaging, 2007, 18(2):127-134.
[3]
Nakada T. Clinical application of high and ultra high-field MRI. Brain & Development, 2007, 29(6): 325-335.
[4]
Yablonskiy DA, Haacke EM. Theory of NMR signal behavior in magnetically inhomogeneous tissues: the static dephasing regime. Magn Reson Med, 1994, 32(6):749-763.
[5]
Bernstein MA, Huston III J, Ward HA. Imaging artifacts at 3.0 T. J Magn Reson Imaging, 2006, 24(4): 735-746.
[6]
Merkle EM, Dale BM, Thomas J, et al. MR liver imaging and cholangiography in the presence of surgical metallic clips at 1.5 and 3 T. Eur Radiol, 2006, 16(10): 2309-2316.
[7]
Graf H, Lauer UA, Berger A, et al. RF artifacts caused by metallic implants or instruments which get more prominent at 3 T: an in vitro study. Magn Reson Imaging, 2005, 23(3): 493-499.
[8]
Wieben O, Francois C, Reeder SB. Cardiac MRI of ischemic heart disease at 3 T: potentials and challenges. Eur J Radiol, 2008, 65(1): 15-28.
[9]
Deshpande VS, Shea SM, Li D. Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency. Magn Reson Med, 2003, 49(5): 803-809.
[10]
Merkle EM, Dale BM. Abdominal MRI at 3.0 T: the basics revisited. AJR Am J Roentgenol, 2006, 186(6):1524-1532.
[11]
Collins CM, Liu W, Schreiber W, et al. Central brightening due to constructive interference with, without, and despite dielectric resonance. J Magn Reson Imaging, 2005, 21(2):192-196.
[12]
Setsompop K, Wald LL, Alagappan V, et al. Parallel RF transmission with eight channels at 3 Tesla. Magn Reson Med, 2006, 56(5): 1163-1171.
[13]
Collins CM, Liu W, Swift BJ, et al. Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequencies. Magn Reson Med, 2005, 54(6):1327-1332.
[14]
Amartur S, Haacke EM. Modified iterative model based on data extrapolation method to reduce Gibbs ringing. J Magn Reson Imaging, 1991, 1(3): 307-317.
[15]
Koktzoglou I, Simonetti O, Li D. Coronary artery wall imaging: initial experience at 3 T. J Magn Reson Imaging, 2005, 21(2): 128-132.

PREV MRI findings and clinical significance of the lumbar endplate osteochondritis
NEXT 3D turbo spin echo imaging technique: SPACE
  



Tel & Fax: +8610-67113815    E-mail: editor@cjmri.cn