Share:
Share this content in WeChat
X
Technical Article
Improved diagnosis of breast diseases with Siemens MR techniques
SUN Zhi-guo 

DOI:10.3969/j.issn.1674-8034.2010.06.014.


[Abstract] With the rapid development of Siemens MR techniques, MR breast imaging can produce images of provide high temporal and spatial resolution, which can provide true and accurate information of breast disease combined with advanced motion correction method. Breast spectroscopy plays a very important role in the differential diagnosis of benign and malignant diseases, and it is used for post-treatment assessment and follow-up. In addition, MR-guided breast biopsy greatly improve the accuracy of differentiation of benign and malignant disease, and it is a useful guidance for breast diseases treatment.
[Keywords] Breast diseases;Magnetic resonance imaging

SUN Zhi-guo Application Department, Siemens Mindit Magnetic Resonance Ltd., Shenzhen 518057, China

*Correspondence to: Sun ZG, E-mail: zhiguo.sun@siemens.com

Conflicts of interest   None.

Received  2010-10-12
Accepted  2010-11-05
DOI: 10.3969/j.issn.1674-8034.2010.06.014
DOI:10.3969/j.issn.1674-8034.2010.06.014.

[1]
Zhang WJ, Zhang X. syngo Orthopedic MRI techniques. Chin J Magn Reson Imaging, 2010, 1(2): 130-132.
[2]
Wang CH, Sun ZG, Zhang Q, et al. syngo NATIVE non-enhanced MR angiography. Chin J Magn Reson Imaging, 2010, 1(3): 214-217.
[3]
Peng WJ, Jiang ZX, Liu PF, et al. Assessment of preoperative MR imaging in breast cancer: unscrambling the COMICE trial. Chin J Magn Reson Imaging, 2010, 1(3): 164-168.
[4]
Moon M, Cornfeld D, Weinreb J. Dynamic contrast-enhanced breast MR imaging. Magn Reson Imaging Clin N Am, 2009, 17(2):351-362.
[5]
Baltzer PA, Benndorf M, Dietzel M,et al. Sensitivity and specificity of unenhanced MR mammography (DWI combined with T2-weighted TSE imaging, ueMRM) for the differentiation of mass lesions. Eur Radiol, 2010, 20(5): 1101-1110.
[6]
Naganawa S, Satake H, Iwano S, et al. Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence. Eur Radiol, 2008, 18(2):337-342.
[7]
Tozaki M, Maruyama K. Current Status and Future Prospects of Proton MR Spectroscopy of the Breast with a 1.5T MR Unit. J Oncol, DOI: . DOI: . DOI: .
[8]
Tozaki M, Yamashiro N, Sakamoto M, et al. Magnetic resonance-guided vacuum-assisted breast biopsy: results in 100 Japanese women. Jpn J Radiol, 2010, 28(7):527-533.

PREV Changes in relaxation value and cerebral blood flow observed in rat brain with delivery of pure oxygen under 7.0 T
NEXT Current status of magnetization transfer imaging in psychiatric disorders
  



Tel & Fax: +8610-67113815    E-mail: editor@cjmri.cn