Share:
Share this content in WeChat
X
Clinical Article
Diagnostic value of MR angiography in aortic dissection
NI Jiong  WANG Pei-jun  WANG Guo-liang  SHAO Zhi-hong  JIANG Hong  ZHANG Wei 

DOI:10.3969/j.issn.1674-8034.2011.02.010.


[Abstract] Objective: To evaluate the value of magnetic resonance angiography (MRA) in diagnosing aortic dissection.Materials and Methods: We retrospectively analyzed MRA findings of 73 aortic dissection (AD) patients. Express and RF-FAST were used in the MR examination. The results were compared with the findings of surgery or DSA.Results: Seventy-three AD patients including DeBakey type Ⅰ 24 cases, DeBakey type Ⅱ 6 cases, DeBakey type Ⅲ 43 cases. Both the sensitivity and the specificity of the presence and the differentiation of aortic dissection were 100%. The sensitivity of the localization of intimal tears was 94.74%, but the specificity was 100%. The sensitivity of the involvement of arch branches was 91.49%, but the specificity was 92.31%.Conclusion: The aortic dissection can be diagnosed by MRA accurately and non-invasive. MRA can provide more useful information to clinical treatment.
[Keywords] Aneurysm, dissecting;Magnetic resonance imaging;Magnetic resonance angiography

NI Jiong Department of Medical Imaging, Tongji Hospital, Tongji University, shanghai 200065, China

WANG Pei-jun* Department of Medical Imaging, Tongji Hospital, Tongji University, shanghai 200065, China

WANG Guo-liang Department of Medical Imaging, Tongji Hospital, Tongji University, shanghai 200065, China

SHAO Zhi-hong Department of Medical Imaging, Tongji Hospital, Tongji University, shanghai 200065, China

JIANG Hong Department of Medical Imaging, Tongji Hospital, Tongji University, shanghai 200065, China

ZHANG Wei Department of Medical Imaging, Tongji Hospital, Tongji University, shanghai 200065, China

*Correspondence to: Wang PJ, E-mail: tongjipjwang@vip.sina.com

Conflicts of interest   None.

Received  2010-08-18
Accepted  2011-01-08
DOI: 10.3969/j.issn.1674-8034.2011.02.010
DOI:10.3969/j.issn.1674-8034.2011.02.010.

[1]
Herfkens RJ, Higgins GB, Hricak H, et al. Nuclear magnetic resonance imaging of the cardiovascular system: normal and pathologic findings. Radiology, 1983, 147(4): 749-759.
[2]
曾蒙苏,金航.聚焦前沿睿智分享:解读美国《心血管磁共振专家共识》.磁共振成像, 2010, 1(5): 330-333.
[3]
Zhao SH, Lu MH, Zhang Y, et al. Clinical application for cardiovascular diseases using 1.5 T senior MR. Chin J Radiol, 2005, 39(6):577-581.
[4]
Du J, Bydder M. High-Resolution Time-Resolved Contrast-Enhanced MR Abdominal and Pulmonary Angiography Using a Spiral-TRICKS Sequence. Magnetic Resonance in Medicine, 2007, 58(3): 631-635.
[5]
Zhang H, Maki JH, Prince MR. 3D Contrast-Enhanced MR Angiography. Journal of Magnetic Resonance Imaging, 2007, 25(1): 13-25.
[6]
Potthast S, Mitsumori L, Stanescu LA, et al. Measuring aortic diameter with different MR techniques: Comparison of three-dimensional (3D) navigated steady-state free-precession (SSFP), 3D contrast-enhanced magnetic resonance angiography (CE-MRA), resonance angiography (CE-MRA), 2D T2 black blood, and 2D cine SSFP. J Magn Reson Imaging, 2010, 31(1):177-184.
[7]
Krishnam MS, Tomasian A, Malik S, et al. Image quality and diagnostic accuracy of unenhanced SSFP MR Angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases. Eur Radiol, 2010, 20(6): 1311-1320.
[8]
DeBakey ME, McCollum CH, Crawford ES, et al. Dissection and dissecting aneurysms of the aorta: twenty-year follow-up of five hundred twenty-seven patients treated surgically. Surgery, 1982, 92(5): 1118-1134.
[9]
Wang ZQ, Liu YQ, Zhang WS, et al. Comparison of SE with GRE cine MRI. J Clini Radiol (China), 1999, 18(11): 671-673.
[10]
Fan ZM, Zhang ZQ, Liu YQ, et al. Diagnostic value of fast breath-hold MRI techniques in Aortic Dissection. Chin J Radiol, 2003, 37(8): 737-741.
[11]
Wang XH, Shao YJ, Xue HQ, et al. Diagnostic value of Multi-slice spiral CT angiography in Aortic Dissection. J Pract Radiol (China), 2009, 25(4): 557-559.
[12]
Prince MR, Grist TM, Debatin JF, et al. 3D contrast MR angiography. 3rd ed. Berlin: Springer, 2003:43-44.
[13]
Zhang HJ, Sun YQ, Fan ZX, et al. Evaluation of MRA in Aortic Dissection diagnosis-comparison of MRA findings with the operative discovery in 136 patients. Chin J Thorac Cardiovase Surg, 2006, 22(3):155-157.
[14]
Lee VS, Martin DJ, Krinsky GA, et al. Gadolinium-enhanced MR angiography: artifacts and pitfalls. AJR Am J Roentgenol, 2000, 175(1):197-205.

PREV Application of magnetic resonance diffusion tensor imaging and fiber tractography to evaluate the value of diagnostic classification of cerebral gliomas
NEXT Artery supply of breast cancer by using VIBRANT dynamic contrast enhanced MR imaging
  



Tel & Fax: +8610-67113815    E-mail: editor@cjmri.cn