Application of magnetic resonance hydrography technique in imaging of inner ear and diagnosis of inner ear diseases
WANG Yun-ling  JIA Lin  WANG Hong  JIA Wen-xiao 

DOI:10.3969/j.issn.1674-8034.2012.01.005.


[Abstract] Objective: To compare 3 kinds of post-processing methods of magnetic resonance hydrography (MRH) technology (MPR, MIP and VR) in the usage of inner ear.Materials and Methods: Thirty-five patients with sensorineural hearing loss (SNHL) and 40 controls were recruited. High-resolution three-dimensional turbo spin echo T2WI (3D TSE T2WI) axial scanning and bilateral oblique sagittal scanning were performed in each subject with the data transmitted to the workstation for reconstruction by ViewForum. The data of inner ear was compared among different reconstruction modalities.Results: (1) Subtle anatomical structures of cochleovestibular nerve, facial nerve, and inner ear could be clearly shown in 80 ears of 40 adults. (2) The height of semicircular canals and diameter of upper and lateral semicircular canals were different between VR and MIP (P=0.001, P=0.000). (3) MPR was superior in displaying CN, FN, SVN and IVN; the scores of VR are higher than that of MPR and MIP in displaying the structure of V, PSC, SSC and HSC.Conclusion: Among the 3 methods of post-processing, MPR is the best to show the nerves of the labyrinth. VR is the best to display the details of inner ear diseases.
[Keywords] Magnetic resonance hydrography;Inner ear diseases;3D TSE T2WI;Sensorineural hearing loss

WANG Yun-ling Imaging Center, the Second Affiliated Hospital of Xinjiang Medical University, Urumuqi 830063, China

JIA Lin Imaging Center, the Second Affiliated Hospital of Xinjiang Medical University, Urumuqi 830063, China

WANG Hong Imaging Center, the Second Affiliated Hospital of Xinjiang Medical University, Urumuqi 830063, China

JIA Wen-xiao * Imaging Center, the Second Affiliated Hospital of Xinjiang Medical University, Urumuqi 830063, China

*Correspondence to: Jia WX, E-mail: jwxxj@sina.com

Conflicts of interest   None.

Received  2011-12-03
Accepted  2011-12-31
DOI: 10.3969/j.issn.1674-8034.2012.01.005
DOI:10.3969/j.issn.1674-8034.2012.01.005.

[1]
张骥,潘雨辰,周蓉先, 等. 感音神经性耳聋的MRI诊断.临床放射学杂志, 2003, 22(3): 191-193.
[2]
Miyasaka M, Nosaka S, Morimoto N, et al. CT and MR imaging for pediatric cochlear implantation: emphasis on the relationship between the cochlear nerve canal and the cochlear nerve. Pediatr Radiol, 2010, 40(9): 1509-1516.
[3]
Aschendorff A. Imaging in cochlear implant patients. Laryngorhinootologie, 2011, 90 (Suppl 1): S16-21.
[4]
Pyykko I, Zou J, Poe D, et al. Magnetic resonance imaging of the inner ear in Meniere's disease. Otolaryngol Clin North Am, 2010, 43(5): 1059-1080.
[5]
张迪,路虹,徐鸥, 等. 磁共振内耳水成像在大前庭水管综合征诊断中的应用. 临床耳鼻咽喉科杂志, 2006, 20(1): 9-10.
[6]
Huang BY, Zdanski C, Castillo M. Aberrant course of the intracranial facial nerve in cases of atresia of the internal auditory canal (IAC). Neuroradiology, 2011, 53(9): 681-687.
[7]
李英,谢敬霞,刘剑羽. 3D-CISS序列在内耳及内听道磁共振成像中的应用. 中国医学影像技术, 2003, 19(4): 415-417.
[8]
杨正汉,冯逢,王霄英. 磁共振成像技术指南. 北京: 人民军医出版社, 2007: 253.
[9]
Byun JS, Kim HJ, Yim YJ, et al. MR imaging of the internal auditory canal and inner ear at 3T: comparison between 3D driven equilibrium and 3D balanced fast field echo sequences. Korean J Radiol, 2008, 9(3): 212-218.
[10]
谢敬霞. 核磁共振新技术研究与临床应用. 北京: 北京医科大学出版社, 2001: 438-444.
[11]
Tomandl BF, Hastreiter P, Eberhardt KE, et al. Virtual labyrin thoscopy: visualiza-tion of the inner ear with interactive direct volume rendering. Radiographics, 2000, 20(2): 547-558.
[12]
Klingebiel R, Bockmuhl U, Werbs M, et al. Visualization of inner ear dysplasias in patients with sensorineural hearing loss. Acta Radiol, 2001, 42(6): 574-581.
[13]
王林省,宋光义,韩丹, 等. 单侧轴位CT多平面重组在诊断大前庭导水管中的价值. 临床放射学杂志, 2008, 27(8): 1023-1026.

PREV Study of magnetic resonance diffusion tensor imaging in diabetic optic neuropathy