Share:
Share this content in WeChat
X
Technical Article
syngo TWIST for dynamic time-resolved MR angiography

DOI:10.3969/j.issn.1674-8034.2012.05.015.


[Abstract] With the advantages of non-invasion, low false positive rate and so on, 3D dynamic contrast-enhanced MRA has been recognized as one MR technique with high diagnostic value and clinical significance. But for conventional contrast-enhanced MRA, it is hard to estimate the time of delayed scanning after contrast injection and eliminate the venous contamination. syngo TWIST technique launched by Siemens achieves significant improvements in temporal and spatial resolution by manipulating the k-space coverage and using in combination with parallel imaging. With syngo TWIST, there is no need to judge the time to peak after contrast injection. We can completely eliminate the venous contamination and use smaller amounts of contrast agent. In this paper, the underlying principles and initial clinical applications for syngo TWIST will be presented which shows the potential to be applied in the assessment of vascular disease..
[Keywords] syngo TWIST;Vascular disease;Assessment;Magnetic resonance imaging

*Correspondence to: Li SR, E-mail: shao.li@siemens.com

Conflicts of interest   None.

致谢: 本文译自MAGNETOM Flash杂志2006第3期"
Received  2012-08-10
Accepted  2012-09-12
DOI: 10.3969/j.issn.1674-8034.2012.05.015
DOI:10.3969/j.issn.1674-8034.2012.05.015.

[1]
Hennig J, Scheffler K, Laubenberger J, et al. Time-resolved projection angiography after bolus injection of contrast agent. Magn Reson Med, 1997, 37(3): 341-345.
[2]
Finn JP, Baskaran V, Carr JC, et al. Thorax: low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution: initial results. Radiology, 2002, 224(3): 896-904.
[3]
Korosec FR, Frayne R, Grist TM, et al. Time-resolved contrast-enhanced 3D MR angiography. Magn Reson Med, 1996, 36(3): 345-351.
[4]
Riederer SJ, Bernstein MA, Breen JF, et al. Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering: design specifications and technical reliability in 330 patient studies. Radiology, 2000, 215(2): 584-593.
[5]
Cashen TA, Carr JC, Shin W, et al, Intracranial Time-Resolved Contrast-Enhanced MR Angiography at 3T. AJNR Am J Neuroradiol, 2006, 27(4): 822-829.
[6]
Fink C, Puderbach M, Ley S, et al. Time-resolved echo-shared parallel MRA of the lung: observer preference study of image quality in comparison with non-echo-shared sequences. Eur Radiol, 2005, 15(10): 2070-2074.
[7]
Pinto C, Hickey R, Carroll TJ, et al. Time-resolved MR Angiography with Generalized Autocalibrating Partially Parallel Acquisition and Time-resolved Echo-sharing Angiographic Technique for Hemodialysis Arteriovenous Fistulas and Grafts. J Vasc Interv Radiol, 2006, 17(6):1003-1009.

PREV Diagonostic value of B-TFE combined with 3D DCE-MRA in Budd-Chiari syndrome
NEXT Recent advances in clinical of skull base chordoma
  



Tel & Fax: +8610-67113815    E-mail: editor@cjmri.cn