Technical Article
Magnetic resonance imaging quality control and parameter optimization
XUE Zheng-he  WANG Yong-feng  ZHAO Yi-bing 

DOI:10.3969/j.issn.1674-8034.2013.06.009.


[Abstract] Magnetic resonance imaging is a multiple parameter imaging examination technology, Its principle is complex, Quality control is conditioned by many factors. In practice, with MRI imaging principle, imaging parameters on the basis of the characteristics and the relations among each other, In order to obtain high quality magnetic resonance image for the purpose of parameter optimization. On the hardware installation, commissioning, Ensure all parameters are within the scope of the qualified. On the scanning technology, The various imaging parameters optimization, portfolio, flexible application. In a relatively short time get the high quality magnetic resonance imaging examination. Provide scientific basis for the diagnosis of the disease.
[Keywords] Magnetic resonance imaging;Quality control

XUE Zheng-he CT, MRI Room, Yanshi City People's Hospital, Yanshi 471900, China

WANG Yong-feng Department of Radiology, the First Hospital of China Medical University, Shenyang 110001, China

ZHAO Yi-bing * Department of Radiology, the First Hospital of China Medical University, Shenyang 110001, China

*Correspondence to: Zhao YB, E-mail: zhaoyibing1985@163.com

Conflicts of interest   None.

Received  2013-06-20
Accepted  2013-08-19
DOI: 10.3969/j.issn.1674-8034.2013.06.009
DOI:10.3969/j.issn.1674-8034.2013.06.009.

[1]
李坤成.中国医用磁共振产业和技术发展现状.磁共振成像, 2011, 2(1): 5-6.
[2]
杨正汉,冯逢,王霄英.磁共振成像技术指南.北京:人民军医出版社, 2007: 424-426.
[3]
赵喜平.磁共振成像系统的原理及其应用.北京:科学出版社, 2000: 407-422.
[4]
黄艳图,何超明.磁共振成像信噪比的评价方法.磁共振成像, 2012, 3(2): 149-152.
[5]
康立丽,余晓锷. MRI图像信噪比影响因素分析.放射学实践, 2001, 16(6): 404.
[6]
雷福章,张台平.磁共振技术参数与影像信号的探讨.中国医学影像技术, 2003, 19(9): 1241-1241.
[7]
康立丽,卢广文,余晓锷,等. MRI扫描参数与信噪比关系的实验研究.中华放射学杂志, 2003, 37(3): 225-227.
[8]
Jung Y, Jashnani Y, Kijowski R, et al. Consistent non-cartesian off-axis MRI quality: calibrating and removing multiple sources of demodulation phase errors. Magn Reson Med, 2007, 57(1): 206-212.
[9]
Edelman RR, Hesselink JR. Clinical magnetic resonance imaging. Philadelphia: Saunders, 1990: 20-23.
[10]
AAPM. Acceptance testing and quality assurance procedures for magnetic resonance imaging facilities. Maryland: AAPM, 2010:14-20.
[11]
韩志成,刘剑,冯伟. MRI的检测参数和质量控制.中国计量, 2007, (8): 56-59.
[12]
Hashemi RH, Bradley WG Jr, Lisanti CJ. The basics of MRI. Baltimoore: Williams & Wilkins, 2004: 153-165.
[13]
Matt A, Bernstein, Kevin F. Handbook of MRI Pulse Sequences. Burlington: Elsevier Academic Press, 2004: 312-323.

PREV 9.4 T MR spectroscopy detection of mesenchymal stem cells into osteoblasts metabolism characteristics
NEXT The concept of human-friendly MRI system and its realization in MAGNETOM Spectra product
  



Tel & Fax: +8610-67113815    E-mail: editor@cjmri.cn