Share:
Share this content in WeChat
X
Clinical Article
Comparison of three dimensional Fast Time-of-flight and standard time-of-flight MR angiography in intracranial arteries
FENG Fei  ZHAO Wu-yi  LI Zhong-hua  DAI Yi  ZHU Yi  DENG Ling-bo  ZOU Li-qiu 

DOI:10.3969/j.issn.1674-8034.2015.06.005.


[Abstract] Objective: To investigate the value of 3D Fast-TOF MRA in intracranial arteries.Materials and Methods: 3D Fast-TOF and 3D standard TOF sequences were performed in 31 patients. MIP images of intracranial arteries were reconstructed. The image quality (including artifacts), carotid artery branches were compared between the two groups. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the source images of both groups were compared.Results: The acquisition time of 3D Fast-TOF group and 3D standard TOF group were 3.31 min and 5.28 min. The image score of carotid artery branches in 3D Fast-TOF group and 3D standard TOF group was 3.21±0.86 and 2.51±0.64 respectively. Significant statistical difference was existed (P<0.01). Demonstration of the carotid artery branches on 3D Fast-TOF group was superior to that of 3D standard TOF group. The image quality scores of the 3D Fast-TOF group and 3D standard TOF group were 4.84±0.58, 4.87±0.56. SNR of 3D Fast-TOF MRA group and 3D Standard TOF group was 161.17, 3D Fast-TOF MRA group; CNR was 124.13±11.28,113.04±29.90. No statistical difference of image quality, SNR and CNR was existed between these tow groups (P>0.05).Conclusion: We demonstrated that 3D Fast-TOF group is a new intracranial MRA technique which could shorten acquisition time, and preserve good imaging quality and high spatial resolution.
[Keywords] Magnetic resonance imaging;Magnetic resonance angiography;3D fast time of flight;Intracranial arterial diseases

FENG Fei Department of medical imaging, Peking University Shenzhen Hospital, Shenzhen 518036, China

ZHAO Wu-yi Siemens Shenzhen Magnetic resonance Ltd, Shenzhen 518057, China

LI Zhong-hua Department of medical imaging, Peking University Shenzhen Hospital, Shenzhen 518036, China

DAI Yi Department of medical imaging, Peking University Shenzhen Hospital, Shenzhen 518036, China

ZHU Yi Department of medical imaging, Peking University Shenzhen Hospital, Shenzhen 518036, China

DENG Ling-bo Department of medical imaging, Peking University Shenzhen Hospital, Shenzhen 518036, China

ZOU Li-qiu* Department of medical imaging, Peking University Shenzhen Hospital, Shenzhen 518036, China

*Correspondence to: Zou LQ, E-mail: baszzlq@163.com

Conflicts of interest   None.

Received  2015-04-03
Accepted  2015-05-05
DOI: 10.3969/j.issn.1674-8034.2015.06.005
DOI:10.3969/j.issn.1674-8034.2015.06.005.

[1]
李明利. 3.0 T MR血管成像的临床应用进展.磁共振成像, 2013, 4(4): 309-313.
[2]
郑玲,张龙江,路莉,等.三维时间飞跃法MR血管成像检出颅内动脉瘤的研究.临床放射学杂志, 2011, 30(9): 1256-1259.
[3]
邹立秋,刘晓怡,刘新,等.平衡稳态自由进动序。列非增强MRA在糖尿病患者足部动脉成像中的应用研究.中华放射学杂志, 2011, 45(8): 757-761.
[4]
Choi CG, Lee DH, Lee JH, et al. Detection of intracranial athrosclerostic steno-occlusive disease with 3D time-of-flight magnetic resonance angiography with sensitivity encoding at 3.0 T. AJNR Am J Neuroradiol, 2007, 28(3): 439-446.
[5]
Willinek WA, Born M, Simon B, et al. Time-of-flight MR Angiography:comparison of 3.0 T imaging and 1.5 T imaging-initial experience. Radiology, 2003, 229(3): 913-920.
[6]
Akashi T, Taoka T, Ochi T, et al. Branching pattern of lenticulostriate arteries observed by MR angiography at 3.0 T. Jpn J Radiol, 2012, 30(4): 331-335.
[7]
顾秀玲,李明华,李永东,等. 3.0 T MR三维时间飞跃法MR血管成像与DSA检出颅内动脉瘤的比较.中华放射学杂志, 2013, 47(1): 49-54.
[8]
刘建,周播江.大脑动脉环的解剖及在磁共振血管成像上的应用.解剖学报, 2014, 45(2): 257-262.
[9]
张薇,许建荣,路清,等.硬皮病患者手指高分辨率MR血管成像的研究初探.磁共振成像, 2011, 2(2): 85-89.
[10]
Shahzad R, Younas F. Detection and characterization of intracranial aneurysms:magnetic resonance angiography versus digital subtraction angriography. J Coll Physicians Surg Pak, 2011, 21(6): 325-329.
[11]
Tang PH, Hui F, Sitoh YY. Intracranial aneurysm detection with 3 T magnetic resonance angiography. Acad Med Singapore, 2007, 36(6): 388-393.
[12]
Habibi R, Krishnam MS, Lohan DG, et al. High-spatial-resolution lower extremity MR angiography at 3.0 T:contrast agent dose comparison study. Radiology, 2008, 248(2): 680-692.

PREV The study of resting state functional magnetic resonance and fiber tracking in multiple sclerosis patients with simple spinal cord involvement
NEXT Value of using contrast-enhanced magnetic resonance imaging for the evaluation of the short-term effects of radiotherapy for nasopharyngeal cancer
  



Tel & Fax: +8610-67113815    E-mail: editor@cjmri.cn