多模态功能磁共振成像在高强度聚焦超声消融子宫肌瘤中的研究进展
蒋雨 黄小华 唐玲玲 秦石泽 钟舒婷

Cite this article as: Jiang Y, Huang XH, Tang LL, et al. Research progress of multimodal functional magnetic resonance imaging in high intensive focused ultrasound ablation of uterus myomas[J]. Chin J Magn Reson Imaging, 2022, 13(4): 162-165.本文引用格式:蒋雨, 黄小华, 唐玲玲, 等. 多模态功能磁共振成像在高强度聚焦超声消融子宫肌瘤中的研究进展[J]. 磁共振成像, 2022, 13(4): 162-165. DOI:10.12015/issn.1674-8034.2022.04.036.


[摘要] 子宫肌瘤是育龄期女性最常见的妇科良性肿瘤,高强度聚焦超声(high intensity focused ultrasound,HIFU)是治疗子宫肌瘤的一种非侵入性技术,依靠超声波的热能和机械能在监控影像的引导下消融靶组织,导致组织凝固性坏死。功能磁共振成像在评估HIFU消融子宫肌瘤的有效性和安全性中发挥了重要作用,能无创提供功能、灌注和代谢信息用于HIFU术前疗效预测、术后疗效评估及观察周围组织变化。本文就多模态功能磁共振成像在HIFU消融子宫肌瘤中的研究进展予以综述。
[Abstract] Uterus myomas are the most common gynecological benign tumors in women of childbearing age. High intensity focused ultrasound (HIFU) is a non-invasive technology for the treatment of uterus myomas, which relies on the thermal and mechanical energy of ultrasound to ablate the target tissue under the guidance of monitoring images, resulting in tissue coagulation necrosis. functional magnetic resonance imaging plays an important role in evaluating the efficacy and safety of HIFU ablation of uterus myomas. It can provide noninvasive functional, perfusion and metabolic information for the prediction of preoperative efficacy, postoperative efficacy evaluation and observation of surrounding tissue changes. This article reviews the research progress of multimodal functional magnetic resonance imaging in HIFU ablation of uterus myomas.
[关键词] 磁共振成像;子宫肌瘤;高强度聚焦超声;疗效评估;动态对比增强磁共振成像;扩散加权成像
[Keywords] magnetic resonance imaging;uterus myoma;high intensive focused ultrasound;efficacy assessment;dynamic contrast-enhanced magnetic resonance imaging;diffusion weighted imaging

蒋雨    黄小华 *   唐玲玲    秦石泽    钟舒婷   

川北医学院附属医院放射科,南充 637000

黄小华,E-mail:15082797553@163.com

作者利益冲突声明:全体作者均声明无利益冲突。


基金项目: 南充市市校合作项目 19SXHZ0429
收稿日期:2021-12-22
接受日期:2022-04-07
中图分类号:R445.2  R737.33 
文献标识码:A
DOI: 10.12015/issn.1674-8034.2022.04.036
本文引用格式:蒋雨, 黄小华, 唐玲玲, 等. 多模态功能磁共振成像在高强度聚焦超声消融子宫肌瘤中的研究进展[J]. 磁共振成像, 2022, 13(4): 162-165. DOI:10.12015/issn.1674-8034.2022.04.036.

       子宫肌瘤是育龄期女性最常见的妇科良性肿瘤,患病率可达25%~50%[1]。子宫肌瘤可能降低患者生活质量[2],且有恶变的可能性[3],应及时进行干预治疗。高强度聚焦超声(high intensity focused ultrasound,HIFU)是治疗子宫肌瘤的一种非侵入性技术,具有精确性、治疗后恢复快和保留生育能力等优点[4, 5, 6],但其有效性和安全性有待进一步研究[7]。影像学在评估HIFU消融子宫肌瘤的有效性和安全性中发挥了重要作用,相较于其他影像学方法,功能磁共振成像(functional magnetic resonance imaging,fMRI)能无创提供活体组织功能、灌注和代谢信息,在HIFU术前疗效预测、术后疗效评估及观察周围组织变化中应用广泛。本文就多模态fMRI在HIFU消融子宫肌瘤中的研究进展予以综述。

1 HIFU消融子宫肌瘤基本原理

       HIFU概念于1942年由Lynn首次提出[8],是近年来发展迅速的一种肿瘤非侵入性局部热消融技术,其原理是依靠超声波的热能和机械能在监控影像的引导下,消融直径几毫米范围内的靶组织[9]。HIFU消融主要有两种机制:热效应和机械效应。热效应是由于局部组织温度迅速升高吸收声能而产生热量,组织温度升高到60℃以上1 s即会导致大多数组织凝固性坏死,发生瞬时不可逆的细胞死亡;而机械效应仅与高强度的声脉冲有关,包括空化、微流和辐射力[10]。HIFU消融子宫肌瘤的效果受肌瘤细胞密集程度和肌瘤血供的影响,纤维组织较少、血供较丰富的肌瘤对HIFU的敏感性较低,消融效果较差,而消融效果与即刻非灌注区体积率(non-perfusion volume ratio,NPVR)呈正相关,临床上常将NPVR作为HIFU疗效的评估指标[11, 12, 13]

2 fMRI在HIFU消融子宫肌瘤中的应用

       目前,fMRI在HIFU术前疗效预测、术后疗效评估及观察周围组织变化中应用的热点主要集中在动态对比增强MRI (dynamic contrast-enhanced MRI,DCE-MRI)、扩散加权成像(diffusion weighted imaging,DWI)、扩散张量成像(diffusion tensor imaging,DTI)和磁共振弹性成像(magnetic resonance elastography,MRE)等。

2.1 DCE-MRI在HIFU消融子宫肌瘤中的应用

       DCE-MRI是一种组织灌注成像技术,可提供转运常数(Ktrans)、血管外细胞外容积分数(Ve)、血浆容积分数(Vp)、回流常数(Kep)、血流量(blood flow,BF)和血容量(blood volume,BV)等血流动力学参数,进而在活体上定量评价组织的微循环、血流灌注和血管通透性变化。由于不同子宫肌瘤细胞结构和微循环特征不同,对热消融的反应有差异,因此DCE-MRI具有预测和评估消融效果的潜在价值。Funaki等[12]根据子宫肌瘤T2加权成像(T2 weighted imaging,T2WI)的信号强度(signal intensity,SI)值简单将其分为三型(1型:肌瘤的SI值与骨骼肌相当;2型:肌瘤的SI值介于骨骼肌和肌层之间;3型:肌瘤的SI值等于或高于肌层),认为3型肌瘤具有高灌注,其NPVR比1型和2型低。但这种基于肌瘤的SI值表征血流灌注预测NPVR的方法易受扫描参数(如恢复时间为125 ms时,肌瘤的SI值总是高于骨骼肌,即不存在Funaki 1型肌瘤[14])和观察者经验的影响,其结果缺乏稳定性和准确性。Zhao等[15]通过DCE-MRI进一步研究T2WI高信号肌瘤之间消融疗效的差异,发现在动脉期(注射对比剂后60 s内)轻微或不规则强化的高信号肌瘤比动脉期规则强化的高信号肌瘤的消融效果好。此外,Łoziński等[16]根据DCE时间-信号强度曲线将子宫肌瘤分为三型(1型为流入型;2型为平台型;3型为流出型)来预测其NPVR,结果提示1型和2型肌瘤的NPVR较3型高,后者可能因血液快速廓清带走热量降低了疗效,这种分类方法能够避免扫描参数和观察者经验对结果的影响。Wei等[17]研究DCE-MRI血流动力学参数与NPVR的关系时发现,子宫肌瘤的Ktrans、BF及BV值与其NPVR呈负相关,且NPVR≥70%组肌瘤的Ktrans、Kep、Ve和BF值均低于NPVR<70%组,表明DCE-MRI定量参数可作为HIFU疗效的预测指标。此外,定量DCE-MRI在评估疗效及机制中也具有一定的价值。王伟等[18]发现DCE-MRI定量参数可评估HIFU术后即时疗效,治疗后的Ktrans、Ve和Vp值与疗效呈正相关。以往研究[19]认为静脉注射催产素可提高肌瘤的消融效果,但尚不清楚这种现象是由催产素对子宫肌层的作用还是由肌瘤本身引起。为探究其机制,Otonkoski等[20]通过定量DCE-MRI灌注技术,发现静脉注射催产素之所以能提高NPVR是因为其能有效减少肌瘤的血流量,而对正常子宫肌层血流量影响较小或无影响。

       DCE-MRI可通过绘制时间-信号强度曲线和测定血流动力学参数预测和评估HIFU消融子宫肌瘤的疗效。但是使用对比剂存在发生全身反应的风险,且后处理时勾画单层感兴趣区(region of interest,ROI)分析得到的参数不能代表子宫肌瘤的总体情况。未来还需进一步研究DCE-MRI及其血流动力学参数,寻找对比剂增强成像的替代方案,减少不良反应的发生,勾画全肿瘤ROI分析定量灌注参数,更可靠、更稳定地预测和评估疗效[21]

2.2 DWI在HIFU消融子宫肌瘤中的应用

       DWI是无创检测活体组织内水分子扩散运动的技术,细胞间隙变小时水分子扩散运动受限,DWI表现为信号增高,相应的ADC值降低,反之ADC值增高。不同子宫肌瘤的微观结构及其在热消融后蛋白质变性和细胞毒性水肿的程度存在差异,这种差异可通过水分子扩散运动的特点表征,因此DWI具有预测和评估消融效果的潜在价值。Verpalen等[22]认为DWI的ADC值可区分子宫肌瘤和子宫肌层,并区分不同的子宫肌瘤类型,可能是预测疗效的有用工具。多项研究表明DWI和ADC值与HIFU消融子宫肌瘤的NPVR密切相关。Sainio等[23]研究ADC值与NPVR之间的相关性,根据ADC值将子宫肌瘤分为三型(1型:ADC≤980×10-6 mm2/s;2型:980×10-6 mm2/s<ADC<1800×10-6 mm2/s;3型:ADC≥1800×10-6 mm2/s),结果提示1型肌瘤消融效果较好,可能获得更高的NPVR,且这种分类法的预测性能优于Funaki分类法。Zheng等[24]从T2WI和DWI得出的ADC图中提取影像组学特征,构建预测HIFU消融子宫肌瘤疗效的机器学习模型,其AUC为0.887、准确度为0.849、敏感度为0.814,具有较高的预测效能。除术前疗效预测外,DWI在HIFU术后疗效评估中也具有一定的价值。Liao等[25]发现HIFU术后平均ADC和DWI信号值均降低,并在DWI图上观察到了高信号环现象,若高信号环完整,则可代替增强MRI来确定肌瘤体积和评估患者的消融效果。刘佳等[26]则使用不同b值下的ADC值评估HIFU消融子宫肌瘤的中期效果(治疗后6个月),发现b≤100 s/mm2时,消融术后ADC值明显下降;b≤200 s/mm2时,消融术后ADC值稍下降但不明显,提示b值的数量和取值对ADC值的变化有较大影响。此外,DWI还可用于观察HIFU消融子宫肌瘤后其周围组织的变化,如王铭洁等[27]研究发现当b=500 s/mm2和b=1500 s/mm2时,耻骨联合损伤区术后ADC值均较术前增高。

       常规DWI和ADC值只能反映扩散的总体情况,为了更加准确地表示组织本身的微观结构信息,有学者提出双指数模型的概念,即体素内不相干运动(intravoxel incoherent motion,IVIM),将水分子扩散和微血管灌注区分开,弥补了常规DWI单指数模型的不足。IVIM主要量化三个参数:反映灌注信息的D*值;反映真实扩散信息的D值;反映灌注效应占总扩散效应比例的f值。Andrews等[28]发现Funaki 3型肌瘤HIFU消融术前ADC值和D值均显著高于1型和2型,这可能是由前者细胞外间质含水量增加或细胞密度降低所致。刘佳等[26]发现b≤1000 s/mm2时,消融术后6个月D值明显上升、f值明显下降、D*值无明显变化。这与权晓华等[29]的研究不同,后者发现消融术后D值明显上升,f值和D*值明显下降,且NPVR>50%组D*值和f值变化明显高于NPVR≤50%组。两项研究的差异可能是所使用的扫描参数不同(如b值的数目和取值不同)或患者复查扫描的时间点不同所致。

       DWI在预测和评估HIFU消融子宫肌瘤的疗效方面已有较多成果和应用,但单b值DWI得出的ADC值只能反映水分子扩散的总体情况,不能获得肌瘤的血流灌注信息,IVIM可区分水分子扩散和微血管灌注,拉伸指数模型可进一步量化体素内扩散成分不均质性和平均扩散率。未来还需进行更多的DWI相关研究,调整和优化b值的数目和取值,以期获得更加全面准确的评估方法。

2.3 DTI在HIFU消融子宫肌瘤中的应用

       DTI是描述水分子扩散大小和方向特征的技术,在DWI的基础上施加更多的梯度方向,从而更充分地揭示水分子在各个方向的扩散差别,反映组织结构特征。平均扩散系数(mean diffusivity,MD)和各向异性分数(fractional anisotropy,FA)是DTI最重要的参数,前者表示水分子扩散的大小,后者表示水分子扩散的方向性、反映扩散受限程度且对微观结构的变化高度敏感。子宫肌瘤的MD和FA值与其细胞数目、结构及细胞外胶原纤维含量有关(与致密肌瘤组织相比,黏液样变性肌瘤组织的MD升高、FA值降低[30]),不同子宫肌瘤微观结构存在差异,对热消融的反应不同,因此DTI具有预测和评估消融疗效的潜在价值。周芳露等[31]发现消融前纤维束密度越小、FA值越大的肌瘤NPVR越高,可能是由于纤维束密度小的肌瘤细胞外相对胶原纤维含量高,FA值较大,有利于吸收热能,消融效果好;而FA值较小的肌瘤可能存在黏液样变性或坏死,不利于热量的沉积,消融效果差。韩雨等[32]的研究发现HIFU消融术后FA值较术前降低,这可能是由于热消融导致的细胞变性坏死所致。

       DTI在预测和评估HIFU消融子宫肌瘤的疗效方面具有较大的优势,但目前研究较少。想要通过DTI更准确地反映组织微观结构和纤维束走形,需要施加更多的梯度方向、保证足够的信噪比和提高空间分辨率,但扫描时间延长。未来还需要在优化DTI扫描参数、提高信噪比和空间分辨率的同时减少扫描时间,发挥其在无创显示肌瘤微观结构和评估HIFU疗效方面的价值。

2.4 MRE在HIFU消融子宫肌瘤中的应用

       MRE是一种无创测量组织硬度的技术,通过特殊的MRI序列来获取弹性波在组织中的传播信息,使用专门的算法反演得出各点弹性的分布图。大部分疾病发生时,病变组织弹性会随之改变,子宫肌瘤含有平滑肌细胞和纤维结缔组织,内部有大量微血管生成,可能使得肌瘤比周围的正常组织硬度高[33]。子宫肌瘤的硬度可揭示不同肌瘤细胞微观结构的异质性[34],而细胞微观结构与HIFU消融的NPVR有关,因此MRE具有预测和评估消融疗效的潜在价值。Ichikawa等[35]认为MRE测量的肌瘤硬度代表肌瘤的纤维化程度,二者呈正相关,且HIFU消融前硬度值较高的肌瘤消融效果较好,这可能是胶原纤维越多的肌瘤越有利于吸收热能,易消融。Jondal等[36]研究子宫肌瘤硬度值与T2WI信号特征之间的相关性,发现硬度较低的肌瘤SI较高,对应的消融效果较差,在一定程度上进一步证明了T2WI高信号的肌瘤消融效果不佳。

       目前,由于MRE需要专门的弹性波激励装置、特殊的成像序列和专门的弹性重构算法,且弹性图的分辨率较低,在预测和评估HIFU消融子宫肌瘤的疗效方面研究较少,未来还需进一步探究MRE在评估HIFU疗效中的应用价值。此外,由于2D MRE不能纠正潜在斜波传播引起的偏差,往往会高估肌瘤硬度[36],故应采用3D MRE容积分析以更准确地反映肌瘤整体生理机制,提供更加可靠的预测和评估依据。

3 小结与展望

       多模态fMRI能无创提供活体组织功能、灌注和代谢信息,可较好地应用于HIFU消融子宫肌瘤术前疗效预测、术后疗效评估及观察周围组织变化。DCE-MRI可定量评价肌瘤组织的微循环、血流灌注和血管通透性变化,但使用MR对比剂存在发生全身反应的风险;DWI可检测肌瘤组织的水分子扩散运动,而IVIM能进一步区分出肌瘤组织的水分子扩散和微血管灌注;DTI可在DWI的基础上施加更多的梯度方向,更好地反映肌瘤组织结构特征,但DTI基于高斯分布,而实际病变组织的水分子扩散运动多基于非高斯分布,基于后者的扩散峰度成像可较真实反映组织微观结构。上述研究的焦点主要在于HIFU术前疗效预测和术后疗效评估,但在观察周围组织变化方面的研究目前集中于常规MRI,而fMRI可提供更多的信息,甚至在组织发生形态学变化前检测到功能改变,可作为今后的研究方向。此外,临床上应通过结合多种fMRI、其他影像学成像和临床指标,全面客观地对HIFU消融子宫肌瘤的有效性和安全性进行评估。

[1]
子宫肌瘤的诊治中国专家共识专家组. 子宫肌瘤的诊治中国专家共识[J]. 中华妇产科杂志, 2017, 52(12): 793-800. DOI: 10.3760/cma.j.issn.0529-567x.2017.12.001.
Chinese Expert Consensus Group on Diagnosis and Treatment of Uterine Leiomyoma. Chinese expert consensus on the diagnosis and treatment of uterine fibroids[J]. Chin J Obstet Gynecol, 2017, 52(12): 793-800. DOI: 10.3760/cma.j.issn.0529-567x.2017.12.001.
[2]
Schlaff WD, Ackerman RT, Al-Hendy A, et al. Elagolix for heavy menstrual bleeding in women with uterine fibroids[J]. N Engl J Med, 2020, 382(4): 328-340. DOI: 10.1056/NEJMoa1904351.
[3]
Al Ansari AA, Al Hail FA, Abboud E. Malignant transformation of uterine leiomyoma[J]. Qatar Med J, 2012, 2012(2): 16. DOI: 10.5339/qmj.2012.2.16.
[4]
Jeng CJ, Ou KY, Long CY, et al. 500 cases of high-intensity focused ultrasound (HIFU) ablated uterine fibroids and adenomyosis[J]. Taiwan J Obstet Gynecol, 2020, 59(6): 865-871. DOI: 10.1016/j.tjog.2020.09.013.
[5]
Marinova M, Ghaei S, Recker F, et al. Efficacy of ultrasound-guided high-intensity focused ultrasound (USgHIFU) for uterine fibroids: an observational single-center study[J]. Int J Hyperthermia, 2021, 38(2): 30-38. DOI: 10.1080/02656736.2021.1939444.
[6]
Anneveldt KJ, van 't Oever HJ, Nijholt IM, et al. Systematic review of reproductive outcomes after High Intensity Focused Ultrasound treatment of uterine fibroids[J]. Eur J Radiol, 2021, 141: 109801. DOI: 10.1016/j.ejrad.2021.109801.
[7]
Krzyzanowski J, Wozniak S, Szkodziak P, et al. Minimally invasive treatment options for uterine fibroids-state-of-the art 2021[J]. Ginekol Pol, 2022. DOI: 10.5603/GP.a2021.0202.
[8]
Lynn JG, Zwemer RL, Chick AJ, et al. A new method for the generation and use of focused ultrasound in experimental biology[J]. J Gen Physiol, 1942, 26(2): 179-193. DOI: 10.1085/jgp.26.2.179.
[9]
Napoli A, Alfieri G, Andrani F, et al. Uterine myomas: focused ultrasound surgery[J]. Semin Ultrasound CT MR, 2021, 42(1): 25-36. DOI: 10.1053/j.sult.2020.08.001.
[10]
Zhou YF. High intensity focused ultrasound in clinical tumor ablation[J]. World J Clin Oncol, 2011, 2(1): 8-27. DOI: 10.5306/wjco.v2.i1.8.
[11]
Yang MJ, Yu RQ, Chen WZ, et al. A prediction of NPVR≥80% of ultrasound-guided high-intensity focused ultrasound ablation for uterine fibroids[J]. Front Surg, 2021, 8: 663128. DOI: 10.3389/fsurg.2021.663128.
[12]
Funaki K, Sawada K, Maeda F, et al. Subjective effect of magnetic resonance-guided focused ultrasound surgery for uterine fibroids[J]. J Obstet Gynaecol Res, 2007, 33(6): 834-839. DOI: 10.1111/j.1447-0756.2007.00665.x.
[13]
Gong CM, Lin ZJ, Lv FJ, et al. Magnetic resonance imaging parameters in predicting the ablative efficiency of high-intensity focused ultrasound for uterine fibroids[J]. Int J Hyperthermia, 2021, 38(1): 523-531. DOI: 10.1080/02656736.2021.1904152.
[14]
Verpalen IM, Anneveldt KJ, Vos PC, et al. Use of multiparametric MRI to characterize uterine fibroid tissue types[J]. MAGMA, 2020, 33(5): 689-700. DOI: 10.1007/s10334-020-00841-9.
[15]
Zhao WP, Chen JY, Chen WZ. Dynamic contrast-enhanced MRI serves as a predictor of HIFU treatment outcome for uterine fibroids with hyperintensity in T2-weighted images[J]. Exp Ther Med, 2016, 11(1): 328-334. DOI: 10.3892/etm.2015.2879.
[16]
Łoziński T, Ciebiera M, Łuczyńska E, et al. Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids-Efficiency Assessment with the Use of Dynamic Contrast-Enhanced Magnetic Resonance Imaging and the Potential Role of the Administration of Uterotonic Drugs[J]. Diagnostics (Basel, Switzerland), 2021, 11(4): 715. DOI: 10.3390/diagnostics11040715.
[17]
Wei C, Fang X, Wang CB, et al. The predictive value of quantitative DCE metrics for immediate therapeutic response of high-intensity focused ultrasound ablation (HIFU) of symptomatic uterine fibroids[J]. Abdom Radiol (NY), 2018, 43(8): 2169-2175. DOI: 10.1007/s00261-017-1426-7.
[18]
王伟, 张暹东, 李祎, 等. 动态增强磁共振成像定量参数对子宫肌瘤高强度聚焦超声治疗效果的即时评估价值初探[J]. 磁共振成像, 2015, 6(8): 603-607. DOI: 10.3969/j.issn.1674-8034.2015.08.009.
Wang W, Zhang XD, Li Y, et al. The preliminary value of DCE-MRI quantitative parameters in high intensity focused ultrasound (HIFU) ablation's immediate effect for uterine fibroids[J]. Chin J Magn Reson Imaging, 2015, 6(8): 603-607. DOI: 10.3969/j.issn.1674-8034.2015.08.009.
[19]
Lozinski T, Filipowska J, Krol P, et al. Oxytocin administration in high-intensity focused ultrasound treatment of myomata[J]. Biomed Res Int, 2018, 2018: 7518026. DOI: 10.1155/2018/7518026.
[20]
Otonkoski S, Sainio T, Komar G, et al. Oxytocin selectively reduces blood flow in uterine fibroids without an effect on myometrial blood flow: a dynamic contrast enhanced MRI evaluation[J]. Int J Hyperthermia, 2020, 37(1): 1293-1300. DOI: 10.1080/02656736.2020.1846792.
[21]
Li CX, Jin C, Liang T, et al. Magnetic resonance-guided high-intensity focused ultrasound of uterine fibroids: whole-tumor quantitative perfusion for prediction of immediate ablation response[J]. Acta Radiol, 2020, 61(8): 1125-1133. DOI: 10.1177/0284185119891692.
[22]
Verpalen IM, Anneveldt KJ, Vos PC, et al. Use of multiparametric MRI to characterize uterine fibroid tissue types[J]. MAGMA, 2020, 33(5): 689-700. DOI: 10.1007/s10334-020-00841-9.
[23]
Sainio T, Saunavaara J, Komar G, et al. Feasibility of apparent diffusion coefficient in predicting the technical outcome of MR-guided high-intensity focused ultrasound treatment of uterine fibroids-a comparison with the Funaki classification[J]. Int J Hyperthermia, 2021, 38(1): 85-94. DOI: 10.1080/02656736.2021.1874545.
[24]
Zheng YN, Chen LP, Liu MQ, et al. Prediction of clinical outcome for high-intensity focused ultrasound ablation of uterine leiomyomas using multiparametric MRI radiomics-based machine leaning model[J]. Front Oncol, 2021, 11: 618604. DOI: 10.3389/fonc.2021.618604.
[25]
Liao DF, Xiao ZB, Lv FR, et al. Non-contrast enhanced MRI for assessment of uterine fibroids' early response to ultrasound-guided high-intensity focused ultrasound thermal ablation[J]. Eur J Radiol, 2020, 122: 108670. DOI: 10.1016/j.ejrad.2019.108670.
[26]
刘佳, 毕忠旭, 刘婧, 等. 体素内不相干运动MRI评估MR引导下高强度聚焦超声消融子宫肌瘤中期治疗效果[J]. 中国医学影像技术, 2021, 37(8): 1191-1195. DOI: 10.13929/j.issn.1003-3289.2021.08.017.
Liu J, Bi ZX, Liu J, et al. Intravoxel incoherent motion MRI in assessment of mid-term therapeutic effect of MR-guided high-intensity focused ultrasound for uterine fibroids[J]. Chin J Med Imaging Technol, 2021, 37(8): 1191-1195. DOI: 10.13929/j.issn.1003-3289.2021.08.017.
[27]
王铭洁, 李彩英, 陈妹红, 等. 3.0T MRI联合弥散加权成像在子宫肌瘤高聚焦超声术后早期对邻近周围组织影响的评价[J]. 河北医科大学学报, 2018, 39(1): 86-90, 96. DOI: 10.3969/j.issn.1007-3205.2018.01.019.
Wang MJ, Li CY, Chen MH, et al. Evaluation of the effects of 3.0 T MRI combined with diffusion weighted imaging on the adjacent tissues in the early postoperative period of high-intensity focused ultrasound in uterine leiomyoma[J]. J Hebei Med Univ, 2018, 39(1): 86-90, 96. DOI: 10.3969/j.issn.1007-3205.2018.01.019.
[28]
Andrews S, Yuan Q, Bailey A, et al. Multiparametric MRI characterization of funaki types of uterine fibroids considered for MR-guided high-intensity focused ultrasound (MR-HIFU) therapy[J]. Acad Radiol, 2019, 26(4): e9-e17. DOI: 10.1016/j.acra.2018.05.012.
[29]
权晓华, 王康. 体素内不相干运动扩散加权磁共振成像在HIFU治疗子宫肌瘤疗效中的评估价值[J]. 医学临床研究, 2021, 38(3): 379-381. DOI: 10.3969/j.issn.1671-7171.2021.03.017.
Quan XH, Wang K. Value of intravoxel incoherent motion diffusion weighted imaging in evaluating efficacy of HIFU in the treatment of uterine leiomyoma[J]. Acta Agric Shanghai, 2021, 38(3): 379-381. DOI: 10.3969/j.issn.1671-7171.2021.03.017.
[30]
Thrippleton MJ, Bastin ME, Munro KI, et al. Ex vivo water diffusion tensor properties of the fibroid uterus at 7 T and their relation to tissue morphology[J]. J Magn Reson Imaging, 2011, 34(6): 1445-1451. DOI: 10.1002/jmri.22793.
[31]
周芳露, 吕富荣, 吕发金, 等. 术前DTI纤维束示踪成像定量参数与高强度聚焦超声消融子宫肌瘤疗效的相关性研究[J]. 临床放射学杂志, 2020, 39(1): 206-211. DOI: 10.13437/j.cnki.jcr.2020.01.043.
Zhou FL, Lv FR, Lv FJ, et al. The predictive value of quantitative DTI fibre tractography metrics for ablation effect of high intensity focused ultrasound in treating uterine fibroids[J]. J Clin Radiol, 2020, 39(1): 206-211. DOI: 10.13437/j.cnki.jcr.2020.01.043.
[32]
韩雨, 孙成凤, 王习, 等. 扩散张量成像评价子宫肌瘤高强度聚集超声刀治疗前后的临床价值[J]. 实用医学杂志, 2017, 33(15): 2486-2488.
Han Y, Sun CF, Wang X, et al. Clinical value of dti in evaluation of high intensity focused ultrasound in uterine fibroids[J]. J Pract Med, 2017, 33(15): 2486-2488.
[33]
Obrzut M, Obrzut B, Zmuda M, et al. Uterine leiomyomas: correlation between histologic composition and stiffness via magnetic resonance elastography-a Pilot Study[J]. Ginekol Pol, 2020, 91(7): 373-378. DOI: 10.5603/GP.a2020.0067.
[34]
Stewart EA, Taran FA, Chen J, et al. Magnetic resonance elastography of uterine leiomyomas: a feasibility study[J]. Fertil Steril, 2011, 95(1): 281-284. DOI: 10.1016/j.fertnstert.2010.06.004.
[35]
Ichikawa S, Motosugi U, Omori M, et al. MR-guided focused ultrasound for uterine fibroids: a preliminary study of relationship between the treatment outcomes and factors of MR images including elastography[J]. Magn Reson Med Sci, 2019, 18(1): 82-87. DOI: 10.2463/mrms.tn.2017-0103.
[36]
Jondal DE, Wang J, Chen J, et al. Uterine fibroids: correlations between MRI appearance and stiffness via magnetic resonance elastography[J]. Abdom Radiol (NY), 2018, 43(6): 1456-1463. DOI: 10.1007/s00261-017-1314-1.

上一篇 深度学习和影像组学在脑胶质瘤中的研究进展
下一篇 基于MRI深度学习在膝关节前交叉韧带损伤的研究进展
  
诚聘英才 | 广告合作 | 免责声明 | 版权声明
联系电话:010-67113815
京ICP备19028836号-2