Feasibility study on application of MAGiC sequence in sacroiliac joint of young volunteers
ZHAN Yingying  JIANG Yunping  ZHANG Ke  LI Wenjuan  PAN Jielin  FANG Yijie  LI Shaolin  HONG Guobin 

Cite this article as: Zhan YY, Jiang YP, Zhang K, et al. Feasibility study on application of MAGiC sequence in sacroiliac joint of young volunteers. Chin J Magn Reson Imaging, 2020, 11(7): 568-572. DOI:10.12015/issn.1674-8034.2020.07.018.


[Abstract] Objective: To explore the feasibility of applying magnetic resonance image compilation (MAGiC) sequence to MR examination of sacroiliac joint in young volunteers.Materials and Methods: All participants (14 male, 16 female) underwent conventional sequences and MAGiC sequence scanning. Image quality, atifacts, the signal to noise ratio (SNR) and the carrier to noise ratio (CNR) were assessed independently by two observers (a radiologist and a radiologic technologist) on both conventional sequences (T1WI-FSE, T2WI-FSE, STIR) and MAGiC sequences (T1WI, T2WI, STIR). Kappa (K) statistic was used to evaluate the consistency of observers. T2 value of subchondral bone were measured on MAGiC T2-mapping images.Results: Thirty young volunteers were performed MR examination (60 sacroiliac joints included). The image quality scores of conventional sequences T1WI, T2WI and STIR were 5 (0), 5 (0) and 5 (0), which of MAGiC reconstruction sequences were 5 (1), 5 (1) and 3 (2), with statistically significant differences (P<0.05). The consistency check between observers showed K> 0.61. The SNR of T1WI sequence and MAGiC T1WI sequence were 12.61±0.37, 13.96±0.52 (t=-2.63, P< 0.05), the CNR of two sequences were 1.06±0.04, 1.18±0.28 (Z=-2.373, P<0.05). The SNR of T2WI sequence and MAGiC T2WI sequence were 12.84±0.48, 112.63±0.45 (t=0.447, P>0.05), the CNR of two sequences were 1.57±0.05, 1.54 (0.03)(Z=-1.486, P>0.05). The SNR of STIR sequence and MAGiC STIR sequence were 8.36 (3.77), 5.73±0.52 (Z=-3.19, P<0.05), the CNR of two sequences were-1.9 (10.29), 0.95±0.08 (Z=-1.46, P>0.05). There was no statistical difference of artifact score between conventional sequences and MAGiC sequences [conventional sequences: 50 cases (83.3%, grade 1), 8 cases (13.3%, grade 2), 2 cases (3.3%, grade 3). MAGiC sequences: 34 cases (56.6%, grade 1), 18 cases (30%, grade 2), 8 cases (13.3%, grade 3), Z=-4.443, P<0.001]. The mean T2 value was (83±8) ms, and the iliac side was slightly higher than sacral side (P<0.05).Conclusions: Though the subjective image quality score of MAGiC sequence images are slightly lower than conventional sequences images, but with higher SNR and CNR, shorter scanning time, more quantitative parameters, MAGiC sequence can be used for MR examination of sacroiliac joint in young volunteers.
[Keywords] magnetic resonance imaging;sacroiliac joint;diagnostic techniques and procedures

ZHAN Yingying Department of Radiology, Fifth Affiliated Hospital, SUN Yat-Sen University, Zhuhai 519000, China

JIANG Yunping Department of Radiology, Fifth Affiliated Hospital, SUN Yat-Sen University, Zhuhai 519000, China

ZHANG Ke Department of Radiology, Fifth Affiliated Hospital, SUN Yat-Sen University, Zhuhai 519000, China

LI Wenjuan Department of Radiology, Fifth Affiliated Hospital, SUN Yat-Sen University, Zhuhai 519000, China

PAN Jielin Department of Radiology, Fifth Affiliated Hospital, SUN Yat-Sen University, Zhuhai 519000, China

FANG Yijie Department of Radiology, Fifth Affiliated Hospital, SUN Yat-Sen University, Zhuhai 519000, China

LI Shaolin Department of Radiology, Fifth Affiliated Hospital, SUN Yat-Sen University, Zhuhai 519000, China

HONG Guobin* Department of Radiology, Fifth Affiliated Hospital, SUN Yat-Sen University, Zhuhai 519000, China

*Correspondence to: Hong GB, E-mail: honggb@mail.sysu.edu.cn

Conflicts of interest   None.

Received  2020-02-28
Accepted  2020-05-21
DOI: 10.12015/issn.1674-8034.2020.07.018
Cite this article as: Zhan YY, Jiang YP, Zhang K, et al. Feasibility study on application of MAGiC sequence in sacroiliac joint of young volunteers. Chin J Magn Reson Imaging, 2020, 11(7): 568-572. DOI:10.12015/issn.1674-8034.2020.07.018.

[1]
刘辉明,尹国平,别非,等.对比集合序列与常规序列头部MR图像质量.中国医学影像技术, 2019, 35(2): 268-271.
[2]
Duchaussoy T, Budzik JF, Norberciak L, et al. Synthetic T2 mapping is correlated with time from stroke onset: a future tool in wake-up stroke management. Eur Radiol, 2019, 29(12): 7019-7026.
[3]
郑作锋,张东坡,毛磊,等.颅脑集成MRI与常规MRI图像质量的对比研究.磁共振成像, 2019, 10(5): 361-365
[4]
Jung Y, Gho SM, Back SN, et al. The feasibility of synthetic MRI in breast cancer patients: comparison of T2 relaxation time with multiecho spin echo T2 mapping method. Br J Radiol, 2018, 92(1093): 20180479.
[5]
Tanenbaum LN, Tsiouris AJ, Johnson AN, et al. Synthetic MRI for clinical neuroimaging: results of the magnetic resonance image compilation (MAGiC) prospective, multicenter, multireader trial. AJNR Am J Neuroradiol, 2017, 38(6): 1103-1110.
[6]
Lee SM, Choi HY, Cheon JE, et al. Image quality at synthetic brain magnetic resonanceimaging in children. Pediatr Radiol, 2017, 47(12): 1638-1647.
[7]
Hagiwara A, Hori M, Cohen-Adad J, et al. Linearity, bias, intrascanner repeatability, and interscanner reproducibility of quantitative multidynamic multiecho sequence for rapid simultaneous relaxometry at 3 T: a validation study with a standardized phantom and healthy controls. Invest Radiol, 2019, 54(1): 39-47.
[8]
Greese J, Diekhoff T, Sieper J, et al. Detection of sacroiliitis by short-tau inversion recovery and T2-weighted turbo spin echo sequences: results from the SIMACT study. J Rheumatol, 2019, 46(4): 376-383.
[9]
Di Giuliano F, Minosse S, Picchi E, et al. Comparison between synthetic and conventional magnetic resonance imaging in patients with multiple sclerosis and controls. MAGMA, 2019, 28: 804-809.
[10]
李飞.骶髂关节T2* mapping成像在AS患者病情评估方面的价值研究.郑州:郑州大学第一附属医院, 2017.
[11]
Albano D, Chianca V, Cuocolo R, et al. T2-mapping of the sacroiliac joints at 1.5 Tesla: a feasibility and reproducibility study. Skeletal Radiol, 2018, 47(12): 1691-1696.
[12]
Vargas MI, Drake-Pérez M, Delattre BMA. Feasibility of a Synthetic MR imaging sequence for spine imaging. AJNR Am J Neuroradiol, 2018, 39(9): 1756-1763.
[13]
Yi J, Lee YH, Song HT, et al. Double-inversion recovery with synthetic magnetic resonance: a pilot study for assessing synovitis of the knee joint compared to contrast-enhanced magnetic resonance imaging. Eur Radiol, 2019, 29(5): 2573-2580.
[14]
Sung S, Kim HS, Kwon JW. MRI assessment of sacroiliitis for the diagnosis of axial spondyloarthropathy: comparison of fat-saturated T2, STIR and contrast-enhancedsequences. Br J Radiol, 2017, 90(1078): 20170090.
[15]
Kang KM, Choi SH, Kim H, et al. The effect of varying slice thickness and interslice gap on T1 and T2 measured with the multidynamic multiecho sequence. Magn Reson Med Sci, 2019, 18(2): 126-133.
[16]
康宁,俎栋林,张宏杰.自旋密度p、弛豫时间T1和T2定量磁共振成像.中国医学影像技术, 2004, 20(12): 1944-1947.
[17]
Drake-Pérez M, Delattre B, Boto J, et al. Normal values of magnetic relaxation parameters of spine components with the synthetic MRI sequence. AJNR Am J Neuroradiol, 2018, 39(4): 788-795.
[18]
姚晓龙,姚娟,郭辉,等. T2mapping序列在早期强直性脊柱炎骶髂关节病变中的应用价值.中国骨质疏松杂志, 2016, 22(3): 348-350, 357.

PREV Combination of CBF and SWI for the changes of the vision areas with directional visual fatigue
NEXT Value of DWI combined with MRS in glioma grade diagnosis
  



Tel & Fax: +8610-67113815    E-mail: editor@cjmri.cn