The study of high-resolution diffusion tensor imaging in thyroid-associated ophthalmopathy
ZHANG Xiaohui  ZHANG Zhiwei  LÜ Fajin  LIU Cun  LONG Jian  YU Bin  LI Yongmei 

Cite this article as: Zhang XH, Zhang ZW, Lü FJ, et al. The study of high-resolution diffusion tensor imaging in thyroid-associated ophthalmopathy[J]. Chin J Magn Reson Imaging, 2021, 12(9): 11-14. DOI:10.12015/issn.1674-8034.2021.09.003.


[Abstract] Objective To study the application of high-resolution MR diffusion readout-segmented of long variable echo-trains diffusion tensor imaging (Resolve DTI) in the early stage of optic nerve microstructure injury in patients with thyroid associated ophthalmopathy (TAO). Materials andMethods Thirty TAO patients and 30 age and sex matched healthy controls (HC) were enrolled in this study. Conventional MRI and Resolve DTI sequences were used to scan the orbit respectively. FA, ADC, AD and RD values of bilateral optic nerves were measured. Quantitative parameters related to DTI of bilateral optic nerves were compared between patients and HC.Results FA value of bilateral optic nerves in TAO patients was significantly lower than that of HC (P=0.009, P=0.003; P<0.05), ADC and AD value had no significant difference (P=0.364, P=0.053, P=0.955, P=0.211; P>0.05), and RD value was higher than that of HC (P=0.010, P=0.009; P<0.05).Conclusions Resolve DTI imaging technology is helpful to provide objective basis for the damage of the early stage of optic nerve microstructure injury in TAO patients, and to provide help for the treatment of optic neuropathy in TAO patients.
[Keywords] thyroid associated ophthalmopathy;optic nerve;readout-segmented of long variable echo-trains diffusion tensor imaging;fractional anisotropy;apparent diffusion coefficient

ZHANG Xiaohui1   ZHANG Zhiwei1   LÜ Fajin1   LIU Cun2   LONG Jian2   YU Bin1   LI Yongmei1*  

1 Department of Radiology, the First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China

2 Department of Endocrinology, the First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China

Li YM, E-mail: lymzhang70@aliyun.com

Conflicts of interest   None.

ACKNOWLEDGMENTS The National Key Research and Development Plan of Ministry of Science and Technology of the People's Republic of China (No. 2016YFC0107109). The Medical Scientific Youth Project of Chongqing Municipal Health and Family Planning Commission of China (No. 2018QNXM004). Chongqing Kewei Joint Medical Research Project (No. 2020MSXM119).
Received  2021-04-24
Accepted  2021-06-22
DOI: 10.12015/issn.1674-8034.2021.09.003
Cite this article as: Zhang XH, Zhang ZW, Lü FJ, et al. The study of high-resolution diffusion tensor imaging in thyroid-associated ophthalmopathy[J]. Chin J Magn Reson Imaging, 2021, 12(9): 11-14. DOI:10.12015/issn.1674-8034.2021.09.003.

[1]
Wang FF, Cheng JL, Zhang Y, et al. Application of MR high-definition resolution readout segmentation of long variable echo-trains diffusion weighted imaging in the diagnosis of thyroid associated ophthalmopathy[J]. Int Eye Sci, 2020, 20(12): 2129-2133.
[2]
Goncalves AC, Gebrim EM, Monteiro ML. Imaging studies for diagnosing Graves' orbitopathy and dysthyroid optic neuropathy[J]. Clinics (Sao Paulo), 2012, 67(11): 1327-1334. DOI: 10.6061/clinics/2012(11)18.
[3]
Chen HH, Hu H, Chen W, et al. Thyroid-associated orbitopathy: evaluating microstructural changes of extraocular muscles and optic nerves using readout-segmented echo-planar imaging-based diffusion tensor imaging[J]. Korean J Radiol, 2020, 21(3): 332-340. DOI: 10.3348/kjr.2019.0053.
[4]
Dolmann PJ. Evaluating Graves' orbitopathy[J]. Best Pract Res Clin Endocrinol Metab, 2012, 26(3): 229-248. DOI: 10.1016/j.beem.2011.11.007.
[5]
Min J, Park M, Choi JW, et al. Inter-vendor and inter-session reliability of diffusion tensor imaging: implications for multicenter clinical imaging studies[J]. Korean J Radiol, 2018, 19(4): 777-782. DOI: 10.3348/kjr.2018.19.4.777.
[6]
Wang MY, Wu K, Xu JM, et al. Quantitative 3-T diffusion tensor imaging in detecting optic nerve degeneration in patients with glaucoma: association with retinal nerve fiber layer thickness and clinical severity[J]. Neuroradiology, 2013, 55(4): 493-498. DOI: 10.1007/s00234-013-1133-1.
[7]
Han JS, Seo HS, Lee YH, et al. Fractional anisotropy and diffusivity changes in thyroid associated orbitopathy[J]. Neuroradiology, 2016, 58(12): 1189-1196. DOI: 10.1007/s00234-016-1764-0.
[8]
Lee H, Lee YH, Suh SI, et al. Characterizing intraorbital optic nerve changes on diffusion tensor imaging in thyroid eye disease before dysthyroid optic neuropathy[J]. J Comput Assist Tomogr, 2018, 42(2): 293-298. DOI: 10.1097/RCT.0000000000000680.
[9]
Politi LS, Godi C, Cammarata G, et al. Magnetic resonance imaging with diffusion weighted imaging in the evaluation of thyroid-associated orbitopathy: getting below the tip of the iceberg[J]. Eur Radiol, 2014, 24(5): 1118-1126. DOI: 10.1007/s00330-014-3103-3.
[10]
Özkan B, Anik Y, Katre B, et al. Quantitative assessment of optic nerve with diffusion tensor imaging in patients with thyroid orbitopathy[J]. Ophthal Plast Reconstr Surg, 2015, 31(5): 391-395. DOI: 10.1097/IOP.0000000000000359.
[11]
Nucci C, Mancino R, Martucci A, et al. 3-T Diffusion tensor imag ing of the optic nerve in subjects with glaucoma: correlation with GDx-VCC, HRT-III and Stratus optical coherence tomography findings[J]. Br J Ophthalmol, 2012, 96(7): 976-980. DOI: 10.1136/bjophthalmol-2011-301280.
[12]
Anik I, Anık Y, Koç K, et al. Evaluation of early visual recovery in pituitary macroadenomas after endoscopic endonasal transsphenoi dal surgery: quantitative assessment with diffusion tensor imaging(DTI)[J]. Acta Neurochir , 2011, 153(4): 831-842. DOI: 10.1007/s00701-011-0942-4.
[13]
Sun SW, Liang HF, Le TQ, et al. Differential sensitivity of in vivo and ex vivo diffusion tensor imaging to evolving optic nerve injury in mice with retinal ischemia[J]. Neuroimage , 2006, 32(3): 1195-1204. DOI: 10.1016/j.neuroimage.2006.04.212.
[14]
Santarelli X, Garbin G, Ukmar M, et al. Dependence of the fractional anisotropy in cervical spine from the number of diffusion gradients, repeated acquisition and voxel size[J]. Magn Reson Imaging, 2010, 28(1): 70-76. DOI: 10.1016/j.mri.2009.05.046.
[15]
Oouchi H, Yamada K, Sakai K, et al. Diffusion anisotropy measurement of brain white matter is affected by voxel size: underestimation occurs in areas with crossing fibers[J]. AJNR Am J Neuroradiol, 2007, 28(6): 1102-1106. DOI: 10.3174/ajnr.A0488.

PREV Preliminary application of amide proton transfer-MRI in diagnosis of nasopharyngeal carcinomas
NEXT Preliminary study on papillary muscle morphology of the left ventricle in patients with hypertrophic cardiomyopathy by cardiac MR imaging
  



Tel & Fax: +8610-67113815    E-mail: editor@cjmri.cn